Alert Type
PSN - Product Support Notification
Risk
Risk Description
Low/Notification
Software Release Notification
Impact
Impact Description
Low/Notification
Software Release Notification
Product Affected
ACX EX MX NFX PTX QFX SRX vSRX
Alert Description
Junos Software Service Release version 23.4R2-S1 is now available for download from the Junos software download site
Download Junos Software Service Release:
Go to
Junos Platforms - Download Software page
Input your product in the "Find a Product" search box
From the Type/OS drop-down menu, select
Junos SR
From the Version drop-down menu, select your version
Click the Software tab
Select the Install Package as need and follow the prompts
Solution
NOTE: This SRN is for 23.4R2-S1.3 which is built on 2024-08-15. If you download 23.4R2-S1 prior to 2024-08-15, please see
TSB85282
[juniper.net]
Junos Software service Release version 23.4R2-S1 is now available.
23.4R2-S1 - List of Fixed issues
PR Number
Synopsis
Category: BBE Autoconfigured DVLAN related issues
1777139
FPC gets stuck at 100% utilization after upgrade from 21.2R1 or below to 21.3R1 or higher release
Product-Group=junos
On Junos MX platforms with PPPoE (point-to-point protocol over ethernet) subscribers over dynamic VLAN (virtual local area network) scenario, FPC (flexible physical interface cards concentrator) gets stuck at 100% after upgrade from 21.2R1 or below to 21.3R1 or higher release. The line card PFE (packet forwarding engine) is busy because of huge punt traffic which is process-switched by the CPU.
PR Number
Synopsis
Category: MX Platform SW - FRU Management
1784438
MX304 not reachable with the power-off failure on the PIC
Product-Group=junos
When an MX304 LMIC is offline due to a power issue, it may take up to 20 minutes for the LMIC to come back online. You can configure event-options to reduce the time to restart the LMIC. See also:
TSB83899
[juniper.net]
PR Number
Synopsis
Category: Dynamic rendering infrastructure
1745615
Telemetry data is not exported in an IS-IS scaled Segment Routing scenario
Product-Group=junos
On all Junos and Junos OS Evolved platforms configured with SR-ISIS and with gRPC/gNMI telemetry, subscription to the path: "/junos/services/segment-routing/sid/usage/" will not work and the output could not be proper. The issue could happen only in scaled configuration (Approximately, 4000 or more per-sid ingress sensors and 4000 or more IPv4/IPv6 per-sid egress sensors are configured).
PR Number
Synopsis
Category: jdhcpd daemon
1818919
JDHCPD core dumps in tcp_io_reader may be seen on ALQ setups when subscriber synchronization happens
Product-Group=junos
DHCP ALQ (Active Leasequery) Sessions go down due to core dumps in JDHCPD (Juniper DHCP Daemon). These JDHCPD core dumps in tcp_io_reader may be seen on ALQ setups when subscriber synchronization happens after the TCP (Transmission Control Protocol) connection comes up.
PR Number
Synopsis
Category: Flow Module
1817211
On SRX Series devices, when using IPv6 Multi-path BGP with MX configured with EVPN, transit SFW traffic experiences packet drops during IPv6 Neighbor discovery refresh.
Product-Group=junos
On SRX Series devices, when using IPv6 Multi-path BGP with MX configured with EVPN, transit SFW traffic experiences packet drops during IPv6 Neighbor discovery refresh.
PR Number
Synopsis
Category: Platform infra to support jvision
1817967
Product annotation missing for sensors for specific platforms
Product-Group=junos
Product annotation files with correct product support/exclude information for specific sensors with respect to platform MX, PTX and EX92XX products. Request customer to enable CLI "set services analytics product-path-check no-path-check" configure to override product annotation issue.
PR Number
Synopsis
Category: Protocol Independant Multicast
1819741
PIM Prune is not sent to upstream
Product-Group=junos
With RPF-vector TLV PIM prune message might not be sent out of upstream interface when corresponding prune message received from last downstream interface (i.e. S, G state needs to be removed).
PR Number
Synopsis
Category: RPD route tables, resolver, routing instances, static routes
1807037
BGP backup routes are installed as primary routes after enabling 'protect core' feature
Product-Group=junos
On all Junos and Junos OS Evolved platforms when Border Gateway Protocol (BGP) multipath is enabled for Layer 3 Virtual Private Network (L3VPN) routes and 'protect core' is enabled on the Virtual Routing and Forwarding (VRF) instance, the backup BGP path is installed as primary path. The Next hop weight value is not updated correctly, it is weight 0x1 instead of weight 0x4000 for the backup.
PR Number
Synopsis
Category: MPC7/8/9 chassis issues
1814801
Faulty MPC8 or MPC9 line cards can lead to spontaneous chassisd crash on certain Junos MX platforms
Product-Group=junos
On Junos MX2008, MX2010, MX2020 platforms, if a faulty MPC8 or MPC9 line card is present in the chassis, chassisd process may crash and triggers routing-engine switchover.
PR Number
Synopsis
Category: ZT/YT pfe infra issues
1817609
Interface Connectivity issue with MPC10E on Member 1, Slot 0 in MX Virtual Chassis
Product-Group=junos
On all Junos in MX-Virtual-Chassis (MXVC) setups involving MPC10E Flexible PIC Concentrators (FPCs) on member #1 in slot #0 causes incorrect interface number conversion, leading to all interfaces being down on this FPC. This problem affects any MXVC configuration with MPC10 FPCs positioned in this slot.
PR Number
Synopsis
Category: Issues related to broadband edge apps (PPP, DHCP) on Trio ch
1788669
Traffic drop due to mac-validate failure on MX platforms
Product-Group=junos
On Junos MX platforms, when subscriber management is enabled and mac-validate is configured on interfaces, traffic drop is seen while attempting to add a new link to an existing AE (Aggregate Ethernet) bundle from a different FPC.
PR Number
Synopsis
Category: Authentication, Authorization, Accounting, PAM (RADIUS/tacplus)
1826666
The console login no longer works after software upgrade when having "system services ... authentication-order ..." configuration stanza
Product-Group=junos
With the "system services ... authentication-order ..." configuration stanza, the console login will no longer work. See also
TSB85280
[juniper.net]
.
PR Number
Synopsis
Category: UI Infrastructure - mgd, DAX API, DDL/ODL
1821845
The system scripts refresh will fail when using load CLI option
Product-Group=junos
On all Junos and Junos OS Evolved platforms when the 'edit system scripts' hierarchy configuration is changed using loading a configuration from a file or the terminal using 'load' option, the scripts refresh will fail.
PR Number
Synopsis
Category: web filterig issues
1806786
UTM Web filtering does not work for HTTPS traffic sent from Google Chrome browser or MS Edge v124
Product-Group=junos
On SRX platforms, Unified Threat Management (UTM) web filtering does not work for Hypertext transfer protocol secure (HTTPS) traffic sent from Google Chrome browser or MS Edge v124.
23.4R2-S1 - List of Known issues
PR Number
Synopsis
Category: SRX1600 MACsec
1812427
Macsec do not work when interface is transparent mode
Product-Group=junos
MACSec is supported in routing mode but not in transparent mode.
Resolved In:
PR Number
Synopsis
Category: EVO L2 Control Plane PRs
1817677
MX and ACX platforms running Virtual Extensible LAN Multi Protocol Label Switching (VX-LAN MPLS) in Data Center Interconnect (DCI) stitching environments will experience catastrophic traffic disruption
Product-Group=junos
On Junos OS and Junos Evolved MX and ACX platforms with VX-LAN symmetric route stitching between data center networks enabled the Control Word (CW) flag changes will trigger catastrophic behavior and traffic disruption in the Packet Forwarding Enginee (PFE)
Resolved In:
evo:24.2R2-EVO evo:24.4R1-EVO junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: to track infrastructure replication bugs
1754351
vmcore on device with evpn-vxlan configs
Product-Group=junos
Graceful Routing Engine Switchover (GRES) not supporting the configuration of a private route, such as fxp0 , when imported into a non-default instance or logical system. Please see KB https://kb.juniper.net/InfoCenter/index?page=content&id=
KB26616
[juniper.net]
resolution rib policy is required to apply as a work-around
Resolved In:
PR Number
Synopsis
Category: Flow Module
1798672
Packet drops on Inter Chassis Datapath (ICD) link in Multinode High Availability (MnHA) configuration
Product-Group=junos
On all SRX platforms with Multinode High Availability (MnHA) configuration, some packets will be dropped when traffic traverses the Inter Chassis Datapath (ICD) link.
Resolved In:
junos:24.2R1 junos:24.3R1
PR Number
Synopsis
Category: IPSEC/IKE VPN
1804965
Traffic loss for VPN going down due to inconsistency between the VPN configuration in the iked and the service-redundancy-group database
Product-Group=junos
On certain SRX platforms using iked (Internet Key Exchange Protocol Daemon) with IPsec (Internet Protocol Security) and MNHA (Multi-Node High Availability) configured, traffic loss can occur when the VPN (Virtual Private Network) service-redundancy-group becomes active and there is a configuration mismatch between the iked and ikemd (Internet Key Exchange Protocol Management Daemon) services. This issue arises if the reconciliation process takes over 5 minutes and the VPN service-redundancy-group switches to backup before completing the reconciliation, especially with a high number of VPN tunnels (up to 16, 000) and VPN IKE traceoptions set to the highest level.
Resolved In:
junos:22.4R3-S4 junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: Security platform jweb support
1810991
Display issue is observed when range option is used to configure destination/source port range in custom application
Product-Group=junos
On Junos SRX platform, J-web shows error message "The maximum length for this field is 9", when range option is used to configure destination/source port range in custom application and if the value is more than 10 characters.
Resolved In:
junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: Layer2 forwarding on EX/NTF/PTX/QFX
1816049
MAC addresses learnt on interfaces part of VLAN with MAC limiting by interface and "drop-and-log" action configured are cleared after VLAN description is changed
Product-Group=junos
On all Junos and Junos Evolved platforms, when "set vlans switch-options interface-mac-limit packet-action drop-and-log" is configured, changing the Virtual Local Area Network (VLAN) description will cause flush of Media Access Control (MAC) addresses learnt on the interfaces part of the VLAN and traffic impact
Resolved In:
evo:21.4R3-S9-EVO evo:22.2R3-S5-EVO evo:22.4R3-S4-EVO evo:23.2R2-S2-EVO evo:23.4R2-S2-EVO evo:24.2R1-S1-EVO evo:24.2R2-EVO evo:24.4R1-EVO junos:21.4R3-S9 junos:22.4R3-S4 junos:23.2R2-S2 junos:24.2R1-S1 junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: PTX1000 platform
1653316
Junos OS: PTX Series: In an FTI scenario MPLS packets hitting reject next-hop will cause a host path wedge condition (CVE-2024-21600)
Product-Group=junos
An Improper Neutralization of Equivalent Special Elements vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on PTX Series allows a unauthenticated, adjacent attacker to cause a Denial of Service (DoS). Please refer to https://supportportal.juniper.net/
JSA75741
[juniper.net]
for more information.
Resolved In:
junos:18.2X75-D67 junos:19.1R3-S11 junos:19.2R3-S8 junos:19.3R3-S9 junos:19.4R3-S11 junos:20.2R3-S7 junos:20.3R3-S6 junos:20.3X75-D36 junos:20.3X75-D41 junos:20.4R3-S8 junos:21.1R3-S4 junos:21.2R3-S6 junos:21.2X32-D10 junos:21.3R3-S3 junos:21.4R3-S5 junos:22.1R2-S2 junos:22.1R3 junos:22.2R2-S1 junos:22.2R3 junos:22.3R1 junos:22.4R2 junos:22.4R3
PR Number
Synopsis
Category: MX Timing software
1738532
[Clocking Solution]:MX480:PTP state went to Freerun and acquiring upon SyncE ESMC is disabled/downgraded from GM or the upstream node one hop above the parent node
Product-Group=junos
PTP state went to Freerun and acquiring before phase-aligning again when the SyncE ESMC is disabled or downgraded from GM or the upstream node one hop above the parent node
Resolved In:
PR Number
Synopsis
Category: KRT Queue issues within RPD
1805427
The rpd process crashes during rpd restart on Junos and Junos Evolved platforms
Product-Group=junos
This is a timing issue during the restart of rpd. When a new rpd comes up, during bulk-sync, the flagged entries are getting deleted later at kernel, which will not be notified to RPD (master rpd), so RPD is unaware of this delete and holds this entry in DBs, which leads to non-sync between kernel and rpd process.
Resolved In:
evo:24.2R2-EVO evo:24.4R1-EVO junos:24.2R1 junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: Track usability related J-Web PR, like UI layout, workflow
1823264
J-Web: Unable to Define NAT Policy Address Names Containing Dots or Slashes
Product-Group=junos
On all SRX Junos platforms, unable to add/edit any field in NAT policy from J-Web if destination address name '.' dot or '/' slash.
Resolved In:
junos:21.4R3-S9 junos:22.4R3-S4 junos:23.2R2-S2 junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: SRX branch platforms
1811858
Monitored-Status keeps Up after CTL link down in branch model SRX HA
Product-Group=junos
After CTL link down, Monitored-Status in "show chassis cluster interfaces" keeps showing "Up" state.
Resolved In:
junos:23.2R2-S2 junos:24.2R2 junos:24.3R1
PR Number
Synopsis
Category: MPC7E, MPC8E and MPC9E timing and synchronization
1791949
[MX] Configured queue is not honored for outbound PTP traffic
Product-Group=junos
Configured queue is not honored for outbound PTP traffic. Instead packets go out on queue 0 or network control queue 3
Resolved In:
evo:24.2R1-EVO evo:24.3R1-EVO junos:21.2R3-S8 junos:23.4R2 junos:24.2R1 junos:24.3R1
PR Number
Synopsis
Category: usf ams related issues
1804616
NSD validation failure results into upgrade failure for Junos MX platforms
Product-Group=junos
On Junos MX240, MX480, MX960 platforms, the Network Security Daemon (nsd) validation fails during upgrades.
Resolved In:
junos:21.4R3-S9 junos:22.4R3-S4 junos:23.2R2-S2 junos:24.2R2 junos:24.3R1
23.4R2-S1: Software Release Notification for JUNOS Software