Alert Type
SRN - Software Release Notification
Product Affected
PTX
Alert Description
Junos Evolved Software Service Release version 20.1R1-S1-EVO is now available for download from the Junos software download site
Download Junos Software Service Release:
Go to
Junos Platforms - Download Software page
Input your product in the "Find a Product" search box
From the Type/OS drop-down menu, select
Junos SR
From the Version drop-down menu, select your version
Click the Software tab
Select the Install Package as need and follow the prompts
Solution
Junos Software service Release version 20.1R1-S1-EVO is now available.
20.1R1-S1-EVO - List of Fixed issues
PR Number
Synopsis
Category: EVO RCB software
1492955
cmdd is crashing when invoked "request system shutdown reboot disk1"
Product-Group=evo
When a user issue "request system shutdown reboot disk1", the cmdd process protests the request by dumping core and ignoring the reboot.
PR Number
Synopsis
Category: Express BT PFE L3 Features
1492707
[cos] [cbf] EVO PTX10004/8/16: After egress PIC offline/online or deactivate/activate triggers, the ipv4 and ipv6 CBF forwarding-table functionality is not working as expected; The AF and NC queues are not transmitting packets from the second egress interface
Product-Group=evo
For EVO PTX10004/8/16 in 20.1R1, Ipv4 and Ipv6 CBF will not work as expected in negative triggers such as PIC offline/online or deactivate/activate or DUT interfaces flapping. Traffic is getting dropped which were supposed to take AF and NC queue to egress out. Whenever CBF enabled, in forwarding block of chip cos bits of incoming packet will be used the choose the egress path, and this broken in this release whenever mentioned triggered carried out.
PR Number
Synopsis
Category: Application controller related issues
1491548
Junos Evolved "aftmand" process may restarts when a user reconfigures OSPF interfaces
Product-Group=evo
We may see a FPC evo-aftmand-zx process core when OSPF is configured and one of the interface in the config undergoes a major change. A major interface config change would involve deletion and re-installation of the interface and its subcomponents in the forwarding path. To recover from this crash, the FPC needs to be rebooted.
PR Number
Synopsis
Category: Interface PRs defect & enhancement requests
1496361
PTX10008 w LC1201 - the ifmand process restarts at IFAManager::findIfaoInSameSubnet
Product-Group=evo
When a user changes an IPv6 address, the ifmand process restarts. No impact to the system.
PR Number
Synopsis
Category: Express PFE CoS Features
1492985
In StrictPriority mode scheduler, low priority traffic may get lesser than the expected share of the port bandwidth.
Product-Group=evo
In StrictPriority mode scheduler, low priority traffic may get lesser than the expected share of the port bandwidth. For a good workaround Just run strict-priority-scheduler with Strict-High/High/Medium-High/Medium-Low and avoid using priority Low.
PR Number
Synopsis
Category: Express ZX PFE L3 Features
1488975
Junos Evolved - flapping an AE bundle causes protocol sessions(ospf) on other AE bundles to go down
Product-Group=evo
When an aggregate Ethernet (AE) bundle goes down and up event happens, the event may cause protocols' adjacencies on other AE bundles to go down.
Modification History
First publication 2020-05-11
20.1R1-S1-EVO: Software Release Notification for JUNOS Evolved Software Version 20.1R1-S1-EVO