Alert Type

PSN - Product Support Notification

Product Affected

QFX3000-G, QFX3000-M

Alert Description

On a QFX3000-G or M QFabric system, if you execute "show interfaces queue <interface-name > source-chassis <> " or "show interfaces queue <interface-name > source-chassis <> " command on a Network Node group CLI, FPC may detach from the Network Node Group and interfaces may flap.

Below is the example of commands.

show interfaces queue xe-1/0/40 source-chassis 1
show interfaces queue xe-1/0/42 source-fpc 1


These commands are only available in Network Node Group CLI ( NW-NG-0).  User can only go to Network Node CLI from Qfabirc CLI  by executing "request component login NW-NG-0" . Network Node CLI is meant for troubleshooting purposes for Juniper Support and users are recommended to use Qfabric CLI.

Solution

DO NOT execute "show interfaces queue <interface-name > source-chassis <> " or "show interfaces queue <interface-name > source-chassis <> command in Network Node Group CLI.

Below 2 commands are not supported on Qfabric.
  1. show interfaces queue <interface-name> source-chassis
  2. show interfaces queue <interface-name> source-fpc

This issue will be fixed in future 12.2X50,13.1X50 Maintenance Releases.These commands will be removed from Network Node CLI .



Contacting Juniper Support
If you have any questions concerning this bulletin please contact the Juniper Technical Assistance Center (JTAC).

Global Support Web @ http://www.juniper.net/support/requesting-support.html
- Web: Case Manager
In the U.S., Canada, and Mexico: 888-314-JTAC
All other countries dial: +1-408-745-9500