Description

Power supply part number and serial number are not displayed in "show chassis hardware" output.

 

root@ACX710-01> show chassis hardware detail no-forwarding
 
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                TUxxxxxxxx        ACX710
Midplane         REV 13   650-103474   TUxxxxxxxx        ACX710DC
Pseudo CB 0
Routing Engine 0          BUILTIN      BUILTIN           RE-ACX710
  flash/s    64 MB  s25fl512s                            Virtio Block Disk
  usb0 (addr 0.1) EHCI root HUB 0      Generic           uhub0
FPC 0                     BUILTIN      BUILTIN           FPC-BUILTIN
  CPU                     BUILTIN      BUILTIN           FPC CPU
  MIC 0                   BUILTIN      BUILTIN           ACX710 24x1GE/24x10GE SFP MIC
    PIC 0                 BUILTIN      BUILTIN           ACX710 24x1GE/24x10GE SFP MIC
      Xcvr 0     ...
... MIC 1 BUILTIN BUILTIN ACX710 16x10/25GE 4x40/100GE SFP MIC PIC 1 BUILTIN BUILTIN ACX710 16x10/25GE 4x40/100GE SFP MIC Power Supply 0 REV 1 Assy,Pwr Sply,DC Feed A,B, Airflow out Fan Tray 0 REV 1 CE5100P2FPB Fan Module, Airflow Out (AFO)

Symptoms

No operation impact due to this issue

Solution

ACX710-DC Power supply is not a Field Replaceable Unit (FRU). Serial number or part number is not important for non-FRUs. There is no operation or management impact expected due to this issue.  

Power supply part number, Serial number are visible for some power supplies.  Change in the display started due to a component change.  Since there is no operation or management impact there will be no correction expected.

Modification History

2025-0620: Initial draft

Related Information

PR1861531