Description

Actions to take with error PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW (0x210206)

Symptoms

Feb 11 14:24:53 fpc3 CMError: /fpc/3/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW (0x210206), scope: pfe, category: functional, severity: major, module: PE Chip, type: Description for PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW, 

Feb 11 14:24:53 fpc3 Performing action get-state for error /fpc/3/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW (0x210206) in module: PE Chip with scope: pfe category: functional level: major, oc_category: default 

Feb 11 14:24:53 fpc3 Performing action cmalarm for error /fpc/3/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW (0x210206) in module: PE Chip with scope: pfe category: functional level: major, oc_category: default 

Feb 11 14:24:53 fpc3 Cmerror Op Set: PE Chip: PE5[5]: DLU: ipipe int_mpls_buf_uflow error (URI: /fpc/3/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_DLU_IPIPE_INT_REG_INT_MPLS_BUF_UFLOW) 

Feb 11 14:24:53 alarmd[14223]: Alarm set: FPC id=150995816, color=RED, class=CHASSIS, reason=FPC 3 Major Errors

Solution

This is a transient memory registry error.

There are high chances that it clears automatically a few minutes after it is logged.

You can monitor the card for 48 hours to confirm no new errors appear.

If the error didn't clear, reboot the line card.

If the issue persists, open a JTAC case for further assistance.

Modification History

2025-02-15 : Article Created