Description

· It was observed that the system is generating "FRU power off" SNMP traps without triggering any corresponding alarms.

· This indicates that the software is correctly detecting changes in power status but is not raising additional alarms, as the power status is being reported directly from the hardware registers.

· The intermittent occurrence of these traps suggests potential instability in the power connections, such as loose cables or fluctuations, which could momentarily register as a power loss. This should clear on its own when the power being received on the switches are stable.

· Additionally, verifying proper grounding is essential to ensure the stable and efficient operation of the switches.

Solution

> Check for the possiblity of power connections, such as loose cables or fluctuations, which could momentarily register as a power loss.

> Verify proper grounding is being provided to the switch.