Description

This article explains the meaning of the "MQSS Error code: 0x2204cd" alarm that is seen on MX Series routers and indicates if any actions need to be taken.

 

Symptoms

The following log messages are seen on the Flexible PIC Concentrator (FPC):

 


Feb 5 08:31:21 XXXX : %PFE-3: fpc1 Cmerror Op Set: MQSS(0): MQSS(0): FI: Protect 2: Parity error detected for bank 21 of CP table - data32_log_err 0x200000, data32_log_address 0x27a  

Feb 5 08:31:22 XXXX alarmd[62986]: %DAEMON-4: Alarm set: FPC color=RED, class=CHASSIS, reason=FPC 1 Major Errors - MQSS Error code: 0x2204cd

Feb 5 08:31:22 XXXX craftd[4879]: %DAEMON-4: Major alarm set, FPC 1 Major Errors - MQSS Error code: 0x2204cd


Solution

1) Users may see a Major alarm reported when MQSS Error code: 0x2204cd is encountered for the first time.

 

2) A MQSS Error code: 0x22076e error is reported whenever there is a transient parity error detected in EACHIP memory Scheduler block hardware when it has been auto-corrected and no further action is required.

 

If the error occurs multiple times, take the FPC offline and bring it online again or restart the FPC during a maintenance window.

 

user@mx> request chassis fpc slot <slot number> offline

 

Wait for a few minutes.

 

user@mx> request chassis fpc slot <slot number> online

 

OR

user@mx> request chassis fpc slot <slot number> restart

 

3) Further Assistance:

If the issue remains unresolved, please contact Juniper Technical Support for further investigation.

Modification History

2025-02-10 : Article Created