Description

For MX10K-LC4800 - The ISSU support for Layer 2 and Layer 3 PFE features is targeted from 25.4R1 release


Symptoms

FPC will be rebooted if ISSU is attempted on non-supported version


root@MX10004-RE1> request vmhost software in-service-upgrade /var/tmp/junos-vmhost-install-mx-x86-64-24.2R1-S2.5.tgz reboot

Chassis ISSU no-enhanced-mode

[Jan 27 15:05:38]:ISSU: set chassis no-enhanced-mode

Chassis ISSU Check Done

[Jan 27 15:05:38]: Starting VMHOST ISSU

[Jan 27 15:05:38]:ISSU: Validating Image

[edit protocols router-advertisement]:

NSR is not supported; packet loss is expected

[edit protocols router-advertisement]:

NSR is not supported; packet loss is expected

FPC 0 will be offlined (In-Service-Upgrade not supported)

FPC 1 will be offlined (In-Service-Upgrade not supported)

Do you want to continue with these actions being taken ? [yes,no]

Solution

Relevant Documentation:

 

Hardware details on LC4800:

https://www.juniper.net/documentation/us/en/hardware/mx-module-reference/mx10008/topics/concept/jnp10k-lc4800-line-card-descripion.html

 

List of Hardware that support ISSU

https://apps.juniper.net/feature-explorer/feature/2392?fn=Unified%20in-service%20software%20upgrade%20(Unified%20ISSU)

Modification History

2025-02-04 : Article Created