Description

Using the SW image junos-vsrx3-x86-64-23.4R2.13 the deployment went fine.

Using the SW image junos-vsrx3-x86-64-24.2R1-S1.10, FPC are stuck in online/ready state and there are fwdd alarms reported

Symptoms

Alarm reported post upgrade -->

root@SRX> show system alarms

2024-11-28 10:33:35 CET Minor Potential slow peers are: FWDD0

 


FPC in online/ready state -->

root@SRX> show chassis fpc pic-status

Nov 28 11:05:53

Slot 0 Online FPC

PIC 0 Ready

 


PFE related show commands go into timeout -->

root@SRX> show security forward-options resource-manager status

error: usp_ipc_client_recv_:ipc_pipe_read() failed read timed out after 5 second(s)

Solution

The issue is addressed and fixed in the JUNOS releases - junos:24.4R2 junos:25.1R1

Modification History

2025-01-22 : Article Created