ACX710 does not recognize GPON OLT 740-124448 reports NON-JNPR after ACX reboot. In this scenario customer has ACX710 running 21.4R3.15 with several GPON OLT SFP+-10G-PON-OLT-20KM. After ACX710 reboot some of the OLTs report error NON-JNPR UNSUPPORTED. The OLT can be recovered with physical re-seat of the OLT. Customer has stated that this type of problem has been seen before, sometimes OLT reseat or another reboot of ACX710. Customer's primary concern is that some clients will remain down after ACX710 reboot and require manual intervention to recover. ACX710> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis 55555 ACX710 Midplane REV 13 650-103474 55555 ACX710DC Pseudo CB 0 Routing Engine 0 BUILTIN BUILTIN RE-ACX710 FPC 0 BUILTIN BUILTIN FPC-BUILTIN CPU BUILTIN BUILTIN FPC CPU MIC 0 BUILTIN BUILTIN ACX710 24x1GE/24x10GE SFP MIC PIC 0 BUILTIN BUILTIN ACX710 24x1GE/24x10GE SFP MIC Xcvr 1 REV 01 740-124448 OLT-E8B470705C52 SFP+-10G-PON-OLT-20KM Xcvr 3 REV 01 740-124448 OLT-E8B47070583E SFP+-10G-PON-OLT-20KM Xcvr 5 NON-JNPR UNSUPPORTED Xcvr 7 REV 01 740-124448 OLT-E8B470705842 SFP+-10G-PON-OLT-20KM Xcvr 9 NON-JNPR UNSUPPORTED Xcvr 11 REV 01 740-124448 OLT-E8B470705C34 SFP+-10G-PON-OLT-20KM Xcvr 13 REV 01 740-124448 OLT-E8B470705C32 SFP+-10G-PON-OLT-20KM Xcvr 14 REV 02 740-013111 N93BZWF SFP-T Xcvr 15 REV 01 740-124448 OLT-E8B470705840 SFP+-10G-PON-OLT-20KM Xcvr 16 REV 02 740-013111 N93BZWJ SFP-T Xcvr 17 REV 01 740-124448 OLT-E8B470705C36 SFP+-10G-PON-OLT-20KM Xcvr 18 REV 02 740-013111 N93BZ1Y SFP-T Xcvr 19 REV 01 740-124448 OLT-E8B470705C30 SFP+-10G-PON-OLT-20KM Xcvr 21 REV 01 740-124448 OLT-E8B470705744 SFP+-10G-PON-OLT-20KM Xcvr 23 NON-JNPR UNSUPPORTED MIC 1 BUILTIN BUILTIN ACX710 16x10/25GE 4x40/100GE SFP MIC PIC 1 BUILTIN BUILTIN ACX710 16x10/25GE 4x40/100GE SFP MIC Xcvr 0 REV 01 740-061000 WTZ11O10020-B QSFP28-100G-CU1M Power Supply 0 REV 1 TU8XDE2606R Assy,Pwr Sply,DC Feed A, Airflow out Fan Tray 0 REV 1 CE5100S5LMB Fan Module, Airflow Out (AFO)
OLTs stop working after ACX710 power cycle.
Requires a physical on-site visit to restore services.
The SFP OLT needs to be re-seated to fully recover.