This article describes the error seen when configuring virtual chassis ports on EX4300-MP switches.
If you try to configure VC ports on EX4300-MP devices, the following error is seen:
{master:0} root> request virtual-chassis vc-port set pic-slot 1 port 3 error: Invalid PIC slot / PIC port
In EX4300-48MP and EX4300-48MP-S switches, you can use only the built-in QSFP+ ports as VCPs to connect the switch in a Virtual Chassis. You cannot configure the ports on the uplink module in EX4300-48MP and EX4300-48MP-S switches to Virtual Chassis ports (VCPs). You cannot configure the built-in QSFP+ ports as network ports. By default, the built-in QSFP+ ports are dedicated VCPs.
2025-01-09: Article created
2025-01-10: Article validated