Description

This article explains about major error : MQSS_CMERROR_DRD_RORD_ENG_SRAM_PAR_PROTECT_FSET_REG_DETECTED_SQVLD_A (0x2203b6)

Symptoms

Major errors alarm raised on FPC:

1 alarms currently active

Alarm time Class Description

2024-10-26 07:38:51 UTC Major FPC 18 Major Errors

 

Log messages:

Oct 26 07:38:26 Router1 fpc18 Error: /fpc/18/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_SRAM_PAR_PROTECT_FSET_REG_DETECTED_SQVLD_A (0x2203b6), scope: pfe, category: functional, severity: major, module: MQSS(0), type: DRD_RORD: Detected: SQ valid memory port A 

Oct 26 07:38:26 Router1 fpc18 Performing action get-state for error /fpc/18/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_SRAM_PAR_PROTECT_FSET_REG_DETECTED_SQVLD_A (0x2203b6) in module: MQSS(0) with scope: pfe category: functional level: major 

Oct 26 07:38:51 Router1 fpc18 Performing action cmalarm for error /fpc/18/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_SRAM_PAR_PROTECT_FSET_REG_DETECTED_SQVLD_A (0x2203b6) in module: MQSS(0) with scope: pfe category: functional level: major 

Oct 26 07:38:51 Router1 fpc18 Performing action disable-pfe for error /fpc/18/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_SRAM_PAR_PROTECT_FSET_REG_DETECTED_SQVLD_A (0x2203b6) in module: MQSS(0) with scope: pfe category: functional level: major 

Oct 26 07:38:51 Router1 fpc18 PFE 0: 'PFE Disable' action performed. Bringing down ifd et-18/0/0 903 

Oct 26 07:38:51 Router1 fpc18 PFE 0: 'PFE Disable' action performed. Bringing down ifd et-18/0/1 904 

Oct 26 07:38:51 Router1 mib2d[9302]: SNMP_TRAP_LINK_DOWN: ifIndex 1644, ifAdminStatus up(1), ifOperStatus down(2), ifName et-18/0/0

Oct 26 07:38:51 Router1 alarmd[9297]: Alarm set: FPC id=150999656, color=RED, class=CHASSIS, reason=FPC 18 Major Errors

Oct 26 07:38:51 Router1 craftd[8684]: Major alarm set, FPC 18 Major Errors

Solution

This major error is caused by an SQ pointer memory parity error detected on the MQSS chip, which is seen on MX routers installed with MPCs that use EACHIP.

 

To resolve the above error, perform the following steps:

 

1. Collect the following show command outputs:

> show log messages

> show log chassisd

> start shell network pfe <fpc#>

> show nvram

> show syslog messages

> show cmerror module brief

 

2. Reboot FPC to recover from disabled PFE and clear this kind of parity error.


TEST@Router1> request chassis fpc slot <slot number> offline
Wait for a few minutes.
TEST@Router1> request chassis fpc slot <slot number> online

 

 

Modification History

2024-10-26 : Article Created