Description

This error occurs because Juniper devices do not allow IP addresses to be configured on both the me0 and vme interfaces simultaneously.

This can lead to unexpected behavior or management difficulties.


VME is a virtual management interface primarily used in Virtual Chassis configurations.

Symptoms

When attempting to configure the VME interface on a standalone Juniper switch (not part of a Virtual Chassis), the interface remains down:

root@switch> show interfaces terse | match vme
vme                up    down
vme.0              up    down   inet     <no-ip-address>

 

And The following error is detected in the logs:

  • Oct 4: UI_CONFIGURATION_ERROR: Process: dcd, path: <none>, statement: <none>, Address cannot be configured on me0 and vme at the same time.

 

Solution

The use of the VME interface is recommended only in Virtual Chassis configurations. For standalone devices, the me0 interface should be used for management. Attempting to configure both interfaces (me0 and vme) simultaneously can lead to unexpected behavior and management difficulties.

Modification History

2024-10-09 : Article Created