EX2300 is shutting down on its own at regular interval.
Observed over-temp logs on chassisd and abnormal shutdown messages will be seen on messages logs:{chassis, shutdown-on-re-over-temperature, 0x3 0x36dd9c}{chassis, overtemp-quick-shutdown, 0x3 0x36ec74}{thermal-health-check, shutdown-timer, 0x3 0x42c0ec}
From messages:eventd[13351]: SYSTEM_ABNORMAL_SHUTDOWN: System abnormally shut downeventd[13351]: SYSTEM_OPERATIONAL: System is operational
Possible cause of the reset/shutdown of the device could be due to high temperature can be caused by several factors such as running on a single fan tray, transient or permanent fan tray failure, or environmental conditions not being met around the device.chassis, shutdown-on-re-over-temperature >> Indicates the chassis process shut down the routing platform due to excessive temperature.> Verify the chassis environment status to check the current temperature. > show chassis environment > Verify the chassis temperature threshold to check whether it is within limit or exceeded the thresholds. > show chassis temperature-thresholds > Kindly verify whether the temperature control best practices is followed in the environment, for more detailed information: Temperature control best practices