PTX10003 may show alarm "RE # SSD Primary minimum supported firmware version mismatch" if the routing-engine is installed with Innodisk SSD.
Customer may observe below alarms.
root@lab> show system alarms no-forwarding
4 alarms currently active
Alarm time Class Description
2022-01-03 15:24:35 +08 Minor RE 0 SSD Primary minimum supported firmware version mismatch
2022-01-03 15:24:36 +08 Minor RE 0 SSD Secondary minimum supported firmware version mismatch
The system is comparing the current Innodisk firmware and available firmware for Swissbit SSD, resulting in false alarm.
root@lab>show system firmware
Part Type Tag. Current Available Status
RE 0 SSD Primary 2 M371112J SBR12059 OK
RE 0 SSD Secondary 3 M371112J SBR12059 OK