This article explains the major/minor alarms "FPC X Hard errors", "FPC X Temp Sensor Fail", and "FPC X Volt Sensor Fail" observed, their causes, and steps to mitigate the issues.
Juniper@Router> show chassis alarms -------------------------------------------------------------------------- 3 alarms currently active Alarm time Class Description XXXX-XX-XX XX:XX:XX +03 Minor FPC XX Temp Sensor Fail XXXX-XX-XX XX:XX:XX +03 Major FPC XX Hard errors XXXX-XX-XX XX:XX:XX +03 Minor FPC XX Volt Sensor Fail
The below Logs are seen on the messages file:
Apr X XX:XX:XX.XXX XXXX SRX alarmd[24146]: %DAEMON-4: Alarm set: FPC id=83887976, color=YELLOW, class=CHASSIS, reason=FPC 7 Temp Sensor Fail
Apr X XX:XX:XX.XXX XXXX SRX craftd[23319]: %DAEMON-4: Minor alarm set, FPC XX Temp Sensor Fail Apr X XX:XX:XX.XXX XXXX SRX alarmd[8425]: %DAEMON-4: Alarm set: FPC id=16778088, color=RED, class=CHASSIS, reason=FPC 7 Hard errors Apr 9 00:30:00.251 2024 SRX craftd[8321]: %DAEMON-4: Major alarm set, FPC XX Hard errors Apr X XX:XX:XX.XXX XXXX SRX alarmd[24146]: %DAEMON-4: Alarm set: FPC id=83887976, color=YELLOW, class=CHASSIS, reason=FPC 7 Volt Sensor Fail Apr 9 00:30:00.251 2024 SRX craftd[23319]: %DAEMON-4: Minor alarm set, FPC XX Volt Sensor Fail
The "FPC XX Temp Sensor Fail" alarm indicates that there is a failure in the temperature sensor of FPC XX. This means that the device is unable to accurately measure the temperature of the FPC XX, which is critical for ensuring proper functioning and preventing overheating issues.
The "FPC XX Hard errors" alarm indicates significant errors detected on FPC XX, which could be related to hardware malfunctions or failures in processing data, this proves to be a hardware issue with FPC
On the other hand, the "FPC XX Volt Sensor Fail" alarm indicates a failure in the voltage sensor of FPC XX. This means that the device is unable to accurately measure the voltage levels on FPC XX, which are essential for ensuring stable and reliable power supply to the components on the FPC.
Before proceeding with RMA for the FPC (linecard), please follow the procedures below:
Reboot / Reseat the FPC (Linecard) and CB
StabilizationWait for the FPC and CB to stabilize before concluding it to be a hardware issue, especially if the FPC/CB or router was recently rebooted.
Helpful Commands for Troubleshooting:
show chassis environment cb
show log messages
show chassis fpc
show system alarms
2024-09-16: New KB Written.
2025-02-27 : dconejomoraRemoving the following step from the KB
We should not ask the customer to complete any physical re-seat