Description

%PFE-3: fpc0 Mem MMU_CTR_UC_DROP_MEM_XPE2_PIPE0 (sbus_addr: 0x29800098), will use hw_only_clear, inst 2, pipe 0

Solution

This log entry indicates a memory management error detected on a Packet Forwarding Engine (PFE) in a network device. Here's a breakdown of the message:

  • Severity Level:%PFE-3
    • This corresponds to a severity level 3 (Error), indicating a significant issue that needs attention but may not cause immediate service disruption.
  • Component:fpc0
  • (Flexible PIC Concentrator 0)
    • Refers to the first FPC in the device, which hosts one or more PICs (Physical Interface Cards) responsible for handling network traffic.
  • Error Description:Mem MMU_CTR_UC_DROP_MEM_XPE2_PIPE0
    • This suggests a memory-related error, specifically involving the Memory Management Unit (MMU) within the PFE. The error pertains to a memory counter drop in the XPE (Crossbar Packet Engine) for pipe 0.
  • Additional Info:
    • sbus_addr: 0x29800098: The address in the hardware where this error was detected.
    • will use hw_only_clear: The system intends to clear this error using hardware mechanisms.
    • inst 2, pipe 0: Refers to the instance and pipe where the error occurred. In this case, it's the second instance (2) and the first pipe (0).

Meaning:

This log message indicates that a memory issue was detected in a specific part of the device (the XPE on FPC0), but the system is handling it automatically by clearing the error via hardware mechanisms. While the device may have mitigated the issue, such errors could indicate potential problems with hardware or memory integrity, especially if they occur frequently, in which case we would need to process an RMA for a device replacement.

Modification History

2024-09-10 : Article Created

Related Information

Checked on qfx5k.