Interface having some number for RX and TX after a while it went to - Inf dBm.
Customer can report Inf dBm in show interfaces diagnostic optics:
user@host> show interfaces diagnostics optics et-0/3/1:0
TX -RX level
Physical interface: et-0/3/1:0
Module temperature : 0 degrees C / 32 degrees F
Module voltage : 0.0000 V
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Module temperature high alarm threshold : 75 degrees C / 167 degrees F
Module temperature low alarm threshold : -5 degrees C / 23 degrees F
Module temperature high warning threshold : 70 degrees C / 158 degrees F
Module temperature low warning threshold : 0 degrees C / 32 degrees F
Module voltage high alarm threshold : 3.6300 V
Module voltage low alarm threshold : 2.9700 V
Module voltage high warning threshold : 3.4640 V
Module voltage low warning threshold : 3.1340 V
Laser bias current high alarm threshold : 130.000 mA
Laser bias current low alarm threshold : 25.000 mA
Laser bias current high warning threshold : 120.000 mA
Laser bias current low warning threshold : 40.000 mA
Laser output power high alarm threshold : 5.0119 mW / 7.00 dBm
Laser output power low alarm threshold : 0.2042 mW / -6.90 dBm
Laser output power high warning threshold : 2.5119 mW / 4.00 dBm
Laser output power low warning threshold : 0.5129 mW / -2.90 dBm
Laser rx power high alarm threshold : 5.0119 mW / 7.00 dBm
Laser rx power low alarm threshold : 0.1023 mW / -9.90 dBm
Laser rx power high warning threshold : 2.5119 mW / 4.00 dBm
Laser rx power low warning threshold : 0.2570 mW / -5.90 dBm
Laser temperature high alarm threshold : 75 degrees C / 167 degrees F
Laser temperature low alarm threshold : -5 degrees C / 23 degrees F
Laser temperature high warning threshold : 70 degrees C / 158 degrees F
Laser temperature low warning threshold : 0 degrees C / 32 degrees F
Lane 0
Laser bias current : 0.000 mA
Laser output power : 0.000 mW / - Inf dBm
Laser receiver power : 0.000 mW / - Inf dBm
From logs we can see alarm set on optics RX-TX power level as well:
Aug 28 08:34:28.359 host-fpc0 picd: PICD_XCVR_LANE_ALARM: xcvr-0/3/1 chan 7 Tx LOS alarm set
Aug 28 08:34:28.359 host-fpc0 picd: PICD_XCVR_LANE_ALARM: xcvr-0/3/1 chan 3 RX LOS alarm set
Aug 28 08:34:28.359 host-fpc0 picd: PICD_XCVR_LANE_ALARM: xcvr-0/3/1 chan 5 Tx CDR LOL alarm set
Aug 28 08:34:28.359 host-fpc0 picd: PICD_XCVR_LANE_ALARM: xcvr-0/3/1 chan 7 Tx CDR LOL alarm set
At the same time interface could report others alarms:
Active alarms : LINK
Active defects : LINK, LOCAL-FAULT
This issue might be reported on both Juniper and non-Juniper XFP
Related case 2024-0829-246714