Description

After upgrade the two-member vc observing commit error, upgrade was completed successfully without any issue.

Symptoms

After upgrade observing commit error on 2 member VC.

 

unable to copy scripts to re:fpc1

commit failed

could not connect to fpc 0: can't asign requested address

Solution

  • After upgrade the VC into 21.4R3-S2.4 while commit the changes, customer observed below error on the chassis

unable to copy scripts to re:fpc1

commit failed

could not connect to fpc 0: can't asign requested address


  • Checked the health status of the chassis and identified MAC addresses flapping between two ports in the mac-learning log.
  • Resolved the issue by disabling the affected port.
  • Attempted commit synchronize and commit synchronize force full, but the issue persisted.
  • Subsequently, hard rebooted FPC1 and tried commit synchronize force full again, which was successful.
  • If the issue persists even after a reboot, please perform a format installation for the affected FPC 

 

Modification History

2024-07-09 : Article Created