The MX480 device encountered FPC Major Error Alarm along with the log/messages below:
fpc7 XMCHIP(0): XMCHIP(0): WO1: Protect: Log Error 0x1, Log Address 0x12, Multiple Errors 0x0
fpc7 CMError: /fpc/7/pfe/0/cm/0/XMCHIP(0)/0/XMCHIP_CMERROR_WO_MEM_PROTECT_FSET_REG_DETECTED_RXFC_FCSN (0x70384), scope: pfe, category: functional, severity: major, module: XMCHIP(0), type: WO_PROTECT: Detected: Parity error for Receive FCSN table
fpc7 Performing action get-state for error /fpc/7/pfe/0/cm/0/XMCHIP(0)/0/XMCHIP_CMERROR_WO_MEM_PROTECT_FSET_REG_DETECTED_RXFC_FCSN (0x70384) in module: XMCHIP(0) with scope: pfe category: functional level: major
fpc7 Performing action cmalarm for error /fpc/7/pfe/0/cm/0/XMCHIP(0)/0/XMCHIP_CMERROR_WO_MEM_PROTECT_FSET_REG_DETECTED_RXFC_FCSN (0x70384) in module: XMCHIP(0) with scope: pfe category: functional level: major
alarmd[63362]: Alarm set: FPC id=150996840, color=RED, class=CHASSIS, reason=FPC 7 Major Errors
craftd[23486]: Major alarm set, FPC 7 Major Errors
fpc7 Performing action disable-pfe for error /fpc/7/pfe/0/cm/0/XMCHIP(0)/0/XMCHIP_CMERROR_WO_MEM_PROTECT_FSET_REG_DETECTED_RXFC_FCSN (0x70384) in module: XMCHIP(0) with scope: pfe category: functional level: major
> show chassis alarms 1 alarms currently active Alarm time Class Description 2024-06-24 03:51:55 UTC Major FPC 7 Major Errors
The logs indicate parity error for Receive FCSN table. The is due to an internal hardware issue in processing the specific packet on the XMCHIP.
A one-time occurrence of this error, not seen with other events, does not indicate a HW problem.This is a transient hardware error that is fixed after rebooting and/or reseating the affected FPC.If the error logs do not clear then please open a case with JTAC .