Description

The Mist UI is displaying the following error: "Log Term Connection Failed". This issue can occur under certain conditions and may impact the functionality of the device. This article provides information on the possible causes and steps to resolve the error.

Symptoms

  • Observed on an SRX-380.
  • The device can resolve and telnet to srx-log-terminator.eu.mist.com 6514, but no flow session can be seen.
  • Running version 20.4R3-S8.2
  • Configured in a chassis cluster setup.

Solution

This issue can be resolved by upgrading to the SRX-Mist recommended version, which is 21.2R3-S7.7. Performing the upgrade to this version should address the issue and ensure proper functionality of the device.

Modification History

2024-05-27 : Article Created

Related Information

[Internal-only] [SRX-Mist] Understanding Limitations: Unable to Upgrade SRX Device from the Mist Cloud

[SRX-Mist] Upgrade Guide: Transitioning to Version 21.2R3-S7.7 from the Mist Cloud