Description

This article explains the meaning of the "MQSS_CMERROR_FO_MEM_PAR_PROTECT_FSET_REG_DETECTED_GFIFO_OMEM (0x220517)" syslog message

Symptoms

Apr 13 07:57:32.458 2024 fpc1 MQSS(2): FO: Parity Protect: Multiple Errors 0x0 

 

Apr 13 07:57:32.459 2024 fpc1 CMError: /fpc/1/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_FO_MEM_PAR_PROTECT_FSET_REG_DETECTED_GFIFO_OMEM (0x220517), scope: pfe, category: functional, severity: minor, module: MQSS(2), type: FO_PAR_PROTECT: Detected: OBUF grant FIFO 

 

Apr 13 07:57:32.459 2024 fpc1 Performing action log for error /fpc/1/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_FO_MEM_PAR_PROTECT_FSET_REG_DETECTED_GFIFO_OMEM (0x220517) in module: MQSS(2) with scope: pfe category: functional level: minor 

 

Apr 13 07:57:32.459 2024 fpc1 Performing action cmalarm for error /fpc/1/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_FO_MEM_PAR_PROTECT_FSET_REG_DETECTED_GFIFO_OMEM (0x220517) in module: MQSS(2) with scope: pfe category: functional level: minor 

 

Apr 13 07:57:32.459 2024 fpc1 Cmerror Op Set: MQSS(2): MQSS(2): FO: Parity Protect: Parity error detected for OBUF grant FIFO (URI: /fpc/1/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_FO_MEM_PAR_PROTECT_FSET_REG_DETECTED_GFIFO_OMEM) 

 

Apr 13 07:57:32.564 2024 chassisd[10868]: CHASSISD_FPC_ASIC_ERROR: <FPC 1> ASIC Error detected errorno 0x00220517 (null)

 

Apr 13 07:57:32.565 2024 alarmd[11330]: Alarm set: FPC id=167772520, color=YELLOW, class=CHASSIS, reason=FPC 1 Minor Errors

Solution

  • The problem indicates a transient hardware error in MQSS CHIP Fabric output block.
  • If the error occurred for the first time , it is recommended to clear the alarm by "clear chassis fpc errors fpc-slot <slot number> all" command(this command do not require MW)and keep monitoring.
  • If the error repeated in a short time , it is recommended to reboot/reseat the FPC in MW
  • If the error repeated after reboot/reseat , then FPC RMA should be considered.

Modification History

2024-05-27 : Article Created