Upon Routing-Engine reseat or replacement the Control-board might be stuck in State 'Present' while the Routing Engine is fully operational and online. re0> show chassis environment cb CB 0 status: State Present Master Bus Revision 247 FPGA Revision 267 CB 1 status: State Online Standby Intake A Temp Sensor 20 degrees C / 68 degrees F Intake B Temp Sensor 19 degrees C / 66 degrees F Exhaust A Temp Sensor 22 degrees C / 71 degrees F Exhaust B Temp Sensor 24 degrees C / 75 degrees F Middle Temp Sensor 25 degrees C / 77 degrees F re0> show chassis routing-engine Routing Engine status: Slot 0: Current state Master Election priority Master Temperature 28 degrees C / 82 degrees F CPU temperature 28 degrees C / 82 degrees F DRAM 119023 MB (128325 MB installed) Memory utilization 7 percent <..> Routing Engine status: Slot 1: Current state Backup Election priority Backup Temperature 26 degrees C / 78 degrees F CPU temperature 26 degrees C / 78 degrees F DRAM 120615 MB (128325 MB installed) Memory utilization 6 percent
Run this command on backup RE to bring the CB online. Note that, this command cannot be run on master CB/RE. > request chassis cb slot <slot> online
This issue is fixed via PR: 1747567