A reachability issue has been observed in a virtual-chassis environment, where certain servers are unable to establish connections with other servers, regardless of whether they reside within the same VLAN or not. If a VC (virtual chassis) is configured with some members in VC mode and for other member(s) in VCF (virtual chassis fabric) mode, it may create some network reachability issue. To resolve this issue, ensure all member are either configured in VC or VCF.
Switch> show virtual-chassis status Preprovisioned Virtual Chassis Virtual Chassis ID: xxxx.xxxx.xxxx Virtual Chassis Mode: Enabled Mstr Mixed Route Neighbor List Member ID Status Serial No Model prio Role Mode Mode ID Interface 0 (FPC 0) Prsnt AAAAAAAAAAAA qfx5100-48s-6q 129 Master* N VC 1 vcp-255/0/48 2 vcp-255/0/50 1 (FPC 1) Prsnt BBBBBBBBBBBB qfx5100-48s-6q 129 Backup N VC 0 vcp-255/0/48 2 vcp-255/0/50 2 (FPC 2) Prsnt CCCCCCCCCCCC qfx5100-48s-6q 0 Linecard N F 0 vcp-255/0/48 1 vcp-255/0/49
To resolve this issue, ensure all members are either configured in VC or VCF.
request virtual-chassis mode