On EX4100 and EX4100-VC switches, alarms related to fan underspeed or overspeed may be observed on the FPCs when fan speed falls below or exceeds predefined thresholds.These alarms can appear even when the fans are functioning normally. This issue has been addressed in newer JUNOS software releases.There is no service impact associated with these alarms.
Customers may observe the following alarms and log messages on the switch
root@switch> show chassis alarms no-forwarding
1 alarms currently activeAlarm time Class Description <date> Minor FPC X Fan X Spinning Underspeed
Fan Underspeed messages:
<date> switch craftd[21980]: Minor alarm set, FPC X Fan X Spinning Underspeed<date> switch alarmd[21739]: Alarm set: FAN id=XXX, color=YELLOW, class=CHASSIS, reason=FPC X Fan X Spinning Underspeed
Or
1 alarms currently activeAlarm time Class Description <date> Minor FPC X Fan X Spinning Overspeed
Fan overspeed messages:
<date> switch craftd[18098]: Minor alarm set, FPC X Fan X Spinning Overspeed<date> switch alarmd[17879]: Alarm cleared: FAN id=XXX, color=YELLOW, class=CHASSIS, reason=FPC X Fan X Spinning Overspeed
This issue has been fixed under PR 1875603(https://prsearch.juniper.net/problemreport/PR1875603)
The Fix will be available in the following Junos releases:
Additionally, the PR will have an enhancement to remove & ignore the fan speed alarms with the command: set chassis alarm ignore-fan-speed-check
2024-04-18 : Article Created
2025-02-20: Updated PR to PR1848292, previous PR was removed from public view as versions had the issue still present