Uplink ports are not coming up, both uplinks appeared down. Uplinks were reseated but they remained down. The switch was powered Cycle in order for it to come online.
Some interfaces won't come up. Logs below will be present:
mist@lab>
% grep I2C messages.0
<11>1 2024-01-31T03:18:18.420Z lab dc-pfe 13585 - - [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x11, errno:8
<163>1 2024-01-31T03:18:18.452Z lab - - - - fpc0 [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x11, errno:8
<163>1 2024-01-31T04:20:01.528Z lab - - - - fpc2 [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x1, errno:8
<163>1 2024-01-31T07:05:41.527Z lab - - - - fpc2 [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x0, errno:8
<11>1 2024-01-31T07:22:23.420Z lab dc-pfe 13585 - - [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x1, errno:8
<163>1 2024-01-31T07:22:23.440Z lab - - - - fpc0 [TVP-BCM-PIC] I2C read failed for Lower byte flag:2 bus:1, i2c addr:0x56, offset:0x1, errno:8
<11>1 2024-01-31T07:48:33.424Z lab lcmd 13584 - - LCMD_I2C_RD_FAIL_AT_ADDR: lcm i2c read failure addr: 3311876 errno: 72
<163>1 2024-01-31T09:24:51.525Z lab - - - - fpc2 [TVP-BCM-PIC] I2C read failed for Upper byte flag:2 bus:1, i2c addr:0x56, offset:0x11, errno:8
% exit
Problem is due to a watchdog SPI transaction causing the interface problem, and will be addressed via new FPGA version.
Resolved-In
junos:21.4R3-S7 junos:22.4R3-S2 junos:23.4R2 junos:24.2R1
https://prsearch.juniper.net/problemreport/PR1789272
https://prsearch.juniper.net/problemreport/PR1789272