Description

This article is intended to explain why the 1G ports are not usable as virtual chassis port (vc-port) on the platforms EX4600.

Symptoms

The customer wants to convert a 1G port into a virtual chassis port, but the same stays in "Absent" state after conversion with the command "> request virtual-chassis vc-port set pic-slot 0 port 0".

 

SWITCH 1

 

{master:0}
user@switch1> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface  Type       Trunk Status    Speed    Neighbor
or               ID         (mbps)    ID Interface
PIC / Port
0/0     Configured        Absent

 

SWITCH 2

 

{master:0}
user@switch2> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface  Type       Trunk Status    Speed    Neighbor
or               ID         (mbps)    ID Interface
PIC / Port
0/0     Configured        Absent

 

Actually, once converted into vc-port and reverted, the port may no longer appear in interfaces terse output.

 

SWITCH 1

 

{master:0}
user@switch1> show interfaces terse | match 0/0/0
gr-0/0/0        up  up
ip-0/0/0        up  up
pfe-0/0/0        up  up
pfe-0/0/0.16383     up  up  inet
pfh-0/0/0        up  up
pfh-0/0/0.16383     up  up  inet
pfh-0/0/0.16384     up  up  inet

 

SWITCH 2

 

{master:0}
user@switch2> show interfaces terse | match 0/0/0
ge-0/0/0        up  up
ge-0/0/0.16386     up  up
gr-0/0/0        up  up-10-05 22:45:09 UTC
ip-0/0/0        up  up
pfe-0/0/0        up  up
pfe-0/0/0.16383     up  up  inet
pfh-0/0/0        up  up
pfh-0/0/0.16383     up  up  inet
pfh-0/0/0.16384     up  up  inet

Solution

The 1G ports are not supposed to be used as vc-ports for best practices, since the vc-ports are intended to handle a large a mount of traffic through the virtual chassis stack. The EX4600 ETHERNET SWITCH DATASHEET also indicates that this platform can use the 10G ports as vc-port, but it does not include 1G ports for this purpose.