This article describes errored syslog caused by PSM(Power Supply Module) failure.Affected platforms: MX10004, MX10008, MX10016, PTX10004, PTX10008, PTX10016.
Following syslog generated and "PSM Not OK" alarm raised.
Mar 10 12:00:01 ptx10k-re0 hwdre: %USER-5-HWD_ALARM_SET_NOTICE: ReportFault: Fault(Location: /Chassis[0]/Psm[0] Device: psm0 Error: psm_d2da_fail) reportedMar 10 12:00:01 ptx10k-re0 hwdre: %USER-5-EMF_EVO_ALARM_SET: Alarm set: PSM color=red, class=CHASSIS, reason=PSM 0 Not OKMar 10 12:00:01 ptx10k-re0 hwdre: %USER-5-HWD_FRU_SNMP_TRAP_NOTICE: SNMP trap generated: jnxPowerSupplyFailure for /Chassis[0]/Psm[0]Mar 10 12:00:01 ptx10k-re0 hwdre: %USER-5-HWD_FRU_SNMP_TRAP_NOTICE: SNMP trap generated: jnxFruFailed for /Chassis[0]/Psm[0]Mar 10 12:00:01 ptx10k-re0 hwdre[22787]: %USER-3: PerformEmfActions: Alarm(Location: /Chassis[0]/Psm[0] Cmpnt: psm0 Module: psm_mcu Error: psm_d2da_fail) reportedMar 10 12:00:01 ptx10k-re0 hwdre[22787]: %USER-5: fru_state_transition /Chassis[0]/Psm[0] ONLINE -> FAULT
"d2d" is short for DC(Direct Current) to DC converter.
There are two d2d converters inside a PSM module: d2da and d2db.Either converter failed will trigger "PSM <slot> Not OK" alarm as well as errored syslog as above.
Please contact JTAC for further troubleshooting.In case of hardware failure, an RMA is needed to replace the affected PSM.
2024-03-13 : Article Created
2024-12-20 : MX10016 and PTX10016 are added as affected platforms.