Description

The alarm indicates there was a mismatch for the installed DRAM size for the RE-S-1800x4.

Symptoms

Dynamic random-access memory (DRAM)is the total physical memory available

When there is a mismatch of available size we will received the below chassis alarm
During issue time there will a difference observed between the installed DRAM size in MB for the RE-S-1800x4 

Chassis alarm -

root@Juniper1800RE> show chassis alarms no-forwarding

1 alarms currently active

Alarm time        Class Description

2024-02-29 02:57:00 IST Minor CPU DRAM size mismatch for Master and Backup RE

 

The below logs are observed during the issue time

 

Messages logs :

 

Feb 29 02:57:00  chassisd[8656]: CHASSISD_REPLICANT_RE_DRAM_SIZE_MISMATCH: RE CPU DRAM size mismatch detected, RE0:32704MB RE1:16320MB

Feb 29 02:57:00  alarmd[9569]: Alarm set: RE id=1073742185, color=YELLOW, class=CHASSIS, reason=CPU DRAM size mismatch for Master and Backup RE

Feb 29 02:57:00  craftd[8660]: Minor alarm set, CPU DRAM size mismatch for Master and Backup RE

 

Chassisd logs :

 

Feb 29 02:57:00 RE CPU DRAM size, RE1:16320

Feb 29 02:57:00 CHASSISD_REPLICANT_RE_DRAM_SIZE_MISMATCH: RE CPU DRAM size mismatch detected, RE0:32704MB RE1:16320MB

Feb 29 02:57:00 send: yellow alarm set, device Routing Engine 1, reason CPU DRAM size mismatch for Master and Backup RE

 

root@Juniper1800RE> show chassis routing-engine no-forwarding

Routing Engine status:

 Slot 0:

  Current state         Master

  Election priority       Master

  Temperature         31 degrees C / 87 degrees F

  CPU temperature       27 degrees C / 80 degrees F

  DRAM           32704 MB (32768 MB installed)

  Memory utilization      7 percent

  5 sec CPU utilization:

   User            6 percent

   Background         0 percent

   Kernel           5 percent

   Interrupt         1 percent

   Idle           89 percent

  1 min CPU utilization:

   User            5 percent

   Background         0 percent

   Kernel           4 percent

   Interrupt         0 percent

   Idle           92 percent

  5 min CPU utilization:

   User            4 percent

   Background         0 percent

   Kernel           3 percent

   Interrupt         0 percent

   Idle           92 percent

  15 min CPU utilization:

   User            4 percent

   Background         0 percent

   Kernel           3 percent

   Interrupt         0 percent

   Idle           93 percent

  Model             RE-S-1800x4

  Serial ID           9016241642

  Start time           2024-02-29 02:51:55 IST

  Uptime             9 days, 35 minutes, 8 seconds

  Last reboot reason       Router rebooted after a normal shutdown.

  Load averages:         1 minute  5 minute 15 minute

                    0.52    0.41    0.36

Routing Engine status:

 Slot 1:

  Current state         Backup

  Election priority       Backup

  Temperature         31 degrees C / 87 degrees F

  CPU temperature       29 degrees C / 84 degrees F

  DRAM           16320 MB (16384 MB installed)<-- This is the total physical memory available: 16GB

  Memory utilization     14 percent

  5 sec CPU utilization:

   User            0 percent

   Background         0 percent

   Kernel           0 percent

   Interrupt         0 percent

   Idle           100 percent

  Model             RE-S-1800x4

  Serial ID           9016241540

  Start time           2024-02-29 02:02:18 IST

  Uptime             9 days, 1 hour, 24 minutes, 41 seconds

  Last reboot reason       Router rebooted after a normal shutdown.

  Load averages:         1 minute  5 minute 15 minute

                    0.20    0.23    0.19

 

Solution

The below action was performed during the issue time to resolve the issue in a MW

Here in the above logs issue is reported for RE1 which is showing less DRAM size in chassisd logs

 

-We checked the RE1 alarm and confirmed the wrong DRAM size present in "show chassis routing-engine"

-Perform a offline/online of CB1 via CLI

-RE 1 will reboot

-If issue still persist after reboot for RE1

-A physical reseat for the RE 1 was performed.

-After the reseat of RE1 the alarm has been cleared

 

 

Modification History

2024-03-12 : Article Created