fpc with minor errors and log ecc_prot_event_handler(7023): XL[0:0].xrif[3].protect ERR 676963 Corrected single bit ECC error @ 0x7c169d8d.
FPC not flapping with minor errors:
Slot 10 information:
State Online
Temperature 46 degrees C / 114 degrees F
Total CPU DRAM 3584 MB
Total XR2 259 MB
Total DDR DRAM 24960 MB
FIPS Capable False
FIPS Mode False
Start time 2022-09-02 11:15:01 UTC
Uptime 550 days, 10 hours, 32 minutes, 43 seconds<<<<<<
Max power consumption 496 Watts
root@router> show chassis alarms no-forwarding
1 alarms currently active
Alarm time Class Description
2024-02-25 05:25:12 UTC Minor FPC 10 Minor Errors
fpc10 ecc_prot_event_handler(7023): XL[0:0].xrif[3].protect ERR 676963 Corrected single bit ECC error @ 0x7c169d8d.
fpc10 ecc_prot_event_handler(7023): XL[0:0].xrif[3].protect ERR 676964 Corrected single bit ECC error @ 0x7c169d8d.
fpc10 ecc_prot_event_handler(7023): XL[0:0].xrif[3].protect ERR 676965 Corrected single bit ECC error @ 0x7c169d8d.
fpc10 ecc_prot_event_handler(7023): XL[0:0].xrif[3].protect ERR 676966 Corrected single bit ECC error @ 0x7c169d8d.
fpc10 Cmerror Op Set: XL[0:0]: XL[0:0].xrif[3].protect ERR 704920 Corrected Single bit ECC error @ 0x7c169d8d. (URI: /fpc/10/pfe/0/cm/0/XL[0:0]/0/LKUP_ASIC_SINGLE_BIT_ECC)
Reboot FPC and this should clear the errors. If errors does not clear, RMA might be required.