Customer is testing MX-SPC3 with MXVC and found if the AMS interface have member mams interface from member1, the SPC3 fails with error "source translation failed".
labroot@jtac-mx960-r2045-re0# run show interfaces load-balancing ams10 detail
Load-balancing interfaces detail
Interface : ams10
State : Up
Last change : 00:26:47
Member count : 1
HA Model : None
Members :
Interface Weight State
mams-14/0/0 10 Active <<<<<<<< member interface from MX-VC member1
NAT pools is not installed:
labroot@jtac-mx960-r2045-re0> show services nat source pool all
{master:member1-re0}
labroot@jtac-mx960-r2045-re0>
If the ams interface having member from mx-vc member 1 SPC3, the NAT source pool is not installed on that corresponding PIC.
This is a day-1 issue for MXVC with MX-SPC3. Problem has been fixed by PR1784696.