Description

Platform details:

Model: ACX6360-OX

Junos: 18.4R1-S7.1 >>> EOS

 

Logs observed:

++++++++

Fans Fan Tray 0                OK        Spinning at normal speed

     Fan Tray 1                    OK        Spinning at normal speed

     Fan Tray 2                    OK        Spinning at normal speed

     Fan Tray 3                    Failed

     Fan Tray 4                    OK        Spinning at normal speed

 

messages.0:Dec 25 00:00:07 **hostname** chassisd[15306]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Fan/Blower Failed (jnxContentsContainerIndex 4, jnxContentsL1Index 4, jnxContentsL2Index 2, jnxContentsL3Index 0, jnxContentsDescr Fan Tray 3 Fan 1, jnxOperatingState 6)

messages.0:Dec 25 00:00:25 ***hostname*** alarmd[15308]: Alarm cleared: FAN color=RED, class=CHASSIS, reason=Fan Tray 3 Fan 1 running at lower speed

 

The above mentioned major alarm is seen as following when one one the fans in fan tray is running at lower speed:

"Fan Tray 3 Fan 1 running at lower speed"

 

Symptoms

Following alarms will be seen:

show chassis alarms

1 alarms currently active

Alarm time              Class Description

2024-01-27 18:04:03 UTC Major Fan Tray 3 Fan 1 running at lower speed

 

Solution

Replace Fan

Note: You must remove the fan module to read the serial number from the serial number ID label. The fan module serial number cannot be viewed through the CLI.