This article explains the minor alarm "SSD at slot [X] (/dev/sdb) encountered errors" on the device and ways to mitigate the same.
root@SRX> show chassis alarms no-forwarding 1 alarms currently active Alarm time Class Description 2023-11-09 10:02:02 UTC Minor SSD at slot 1 (/dev/sdb) encountered errrors. root@SRX> show chassis hardware detail no-forwarding Hardware inventory: Item Version Part number Serial number Description Chassis AAAABBBBBCCCC SRX4600 Midplane REV 59 750-069375 AAAAXXXX SRX4600 Midplane Routing Engine 0 BUILTIN BUILTIN SRX Routing Engine Pseudo CB 0 Mezz REV 16 711-066896 AAAAXXXX Control Mezz Board
Logs:
Nov 9 10:02:02 LCC: [Alarm SET] Object 143 reason 120 Device FRU FPC 0, reason SSD Monitoring Erro(SSD at slot 1 (/dev/sdb) encountered errrors.), color 2, slot 0 Alarm id 2399142008 Nov 9 10:02:02 LCC: send: yellow alarm set, device FRU FPC 0, reason SSD at slot 1 (/dev/sdb) encountered errrors.
In SRX4600, the routing engine is built in with SSD attached to it.To resolve the issue kindly try reseating (unplug/plug) the SSD into the SRX in a safe MW and check if that clears the error.Alarms will clear eventually in sometime after the maintenance is complete.Note:You need to power off the SRX to reseat/replace a SSD from the firewall.
Field-Replaceable Units in an SRX4600 Services Gateway
https://www.juniper.net/documentation/en_US/release-independent/junos/topics/concept/services-gateway-srx4600-frus.html
Replacing an SRX4600 Services Gateway SSD
https://www.juniper.net/documentation/en_US/release-independent/junos/topics/task/installation/services-gateway-srx4600-ssd-replacing.html