A minor alarm for compact-flash was raised as below:User@router> show chassis alarms <...>2023-11-15 02:37:22 -06 Minor Host 0 compact-flash drive error
1. Routing-engine reported a minor alarm, when the compact-flash drive is not initialised properly.
Due to this, we would not be able to see compact-flash information in the hardware list:
User@router> show chassis alarms
1 alarms currently active
Alarm time Class Description2023-11-15 02:37:22 -06 Minor Host 0 compact-flash drive error
Logs sample:Nov 15 02:37:01 send: yellow alarm set, device Routing Engine 0, reason Host 0 compact-flash drive error
2. Compact flash would not be displayed in the "show chassis hardware detail" output:Routing Engine 0 REV 05 740-051822 901628XXXX RE-S-1800x4ada0 28496 MB StorFly - VSFA18PI100B P1X05004584804270785 Disk 1
<<<<< Missing Compact Flashusb0 (addr 0.1) EHCI root HUB 0 Intel uhub0usb1 (addr 0.2) product 0x0020 32 vendor 0x8087 uhub1DIMM 0 D3DV1G1234-XXAA DIE REV-0 PCB REV-0 MFR ID-00DIMM 1 D3DV1G1234-XXIA DIE REV-0 PCB REV-0 MFR ID-00DIMM 2 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00DIMM 3 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00Routing Engine 1 REV 05 740-051822 90162XXXX RE-S-1800x4ada0 28496 MB StorFly - VSFA18PI100A P1T05004493802150071 Disk 1ada1 3998 MB VTDCFAPI004G-KC2 45850-1303 Compact Flashusb0 (addr 0.1) EHCI root HUB 0 Intel uhub0usb1 (addr 0.2) product 0x0020 32 vendor 0x8087 uhub1DIMM 0 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00DIMM 1 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00DIMM 2 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00DIMM 3 D3DV1G1234-XX8IA DIE REV-0 PCB REV-0 MFR ID-00
This could be a hardware issue.
For recovery, we can try to reboot the RE routing-engine and check if the driver initialises properly. If the reboot does not solve the problem, then we need to replace the routing-engine.
2025-04-22 : minor update
2023-11-15 : Article Created