Description

Hard Error alarm is observed on FPC

Symptoms

  • The FPC is offline and not coming up.
  • Hard Errors alarm is observed under "show chassis alarm".
1 alarms currently active
Alarm time               Class  Description
XXXX-XX-XX XX:XX:XX XXX  Major  FPC X Hard errors

  • Also, the below logs are seen in log messages :
Oct XX XX:XX:XX:XXX XXXX CORE chassisd[1409]: %DAEMON-2-CHASSISD_FRU_VERSION_MISMATCH: I2CS version mismatch for FPC X -- expected 1, got 0

Oct XX XX:XX:XX:XXX XXXX CORE chassisd[1409]: %DAEMON-3-CHASSISD_POWER_CHECK: FPC X not powering up

Oct XX XX:XX:XX:XXX XXXX CORE chassisd[1409]: %DAEMON-5-CHASSISD_SNMP_TRAP7: SNMP trap generated: Fru Failed (jnxFruContentsIndex 7, jnxFruL1Index 16, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName FPC: EX8200-48T @ X/*/*, jnxFruType 3, jnxFruSlot X)

Solution

Please follow the below steps to recover the FPC :

 

  • Try to soft-restart the FPC using the below command :
(COMMAND: request chassis fpc slot slot-number (offline | online | restart)

Link to refer: https://www.juniper.net/documentation/us/en/software/junos/chassis/topics/ref/command/request-chassis-fpc.html

 

  • Try to re-seat the affected FPC.

Please make sure that the FPC module is all clean when we re-insert the module.

Link to refer : https://www.juniper.net/documentation/en_US/release-independent/junos/information-products/pathway-pages/ex-series/ex8200/ex8216.pdf

 

  • Insert a known working FPC in the slot, to see if the issue follows with FPC or chassis.

 

Please open a JTAC case to create the RMA for the faulty unit.

Modification History

2023-10-30 : Article Created

2026-09-30 : Externalized