This KB describes the following error and how to clear it:
PECHIP_CMERROR_HMCIF_LINK0_INT_REG_HMC_ERR_MAJOR (0x210087)
root@lab_re0> show chassis alarms no-forwarding 1 alarms currently active Alarm time Class Description 2023-07-30 00:23:06 EDT Major FPC 0 Major Errors
The following syslog message is seen:
/fpc/0/pfe/0/cm/0/PE_Chip/0/PECHIP_CMERROR_HMCIF_LINK0_INT_REG_HMC_ERR_MAJOR (0x210087) in module: PE Chip with scope: pfe category: memory level: major Jul 30 00:23:08 bx6-seattle fpc0 Cmerror Op Set: PE Chip: pe0[0]: HMCIF: Link0: HMC Major Error cmd:62 lng:1 ltag:0 dinv:0 errstat:31 err_cnt:0xc0 Jul 30 00:23:08 bx6-seattle fpc0 Performing action get-state for error
Reset the FPC during a maintenance window clear the alarm.
request chassis fpc slot slot-number <FPC_SLot> (offline | online | restart)
For more information on FPC restart, refer to the documentation on request chassis fpc.
2023-09-25: KB Created