Customer has alarms related to FAN tray and PEM. wanted to know if it's a hardware issue.
show chassis alarms no-forwarding
6 alarms currently active
Alarm time Class Description
2023-09-07 11:32:35 EDT Major Fan Tray 3 I2C Access Error
2023-09-07 11:32:31 EDT Major Fan Tray 2 I2C Access Error
2023-09-07 11:32:29 EDT Major Fan Tray 1 I2C Access Error
2023-09-07 11:32:25 EDT Major Fan Tray 0 I2C Access Error
2023-09-07 11:29:26 EDT Major PEM 0 I2C Failure
2023-09-07 11:27:52 EDT Major PEM 1 I2C Failure
On TVP platforms, If there is an I2C failure, the I2C controller will be trapped in an error condition. All I2C access will fail after that failure. Alarms will be generated for I2C failure.
Temporary workaround --rebooting box.
Permanent fix:
Fix based on code for avoiding this anomaly in behavior to report inconsistent alarm failure junos:21.4R3-S5 junos:22.1R3-S4 junos:22.2R3-S2 junos:22.3R3-S1 junos:22.4R1 junos:23.1R1