On Juniper Networks QFX5110 VC. The "show chassis environment" output will show the PEM and FAN tray status of backup member as absent. Although, the units will work normal without any issue
> show chassis environment no-forwarding
Class Item Status Measurement
Power FPC 0 Power Supply 0 OK 52 degrees C / 125 degrees F
FPC 0 Power Supply 1 OK 53 degrees C / 127 degrees F
FPC 1 Power Supply 0 Absent
FPC 1 Power Supply 1 Absent
Fans FPC 0 Fan Tray 0 Fan 0 OK Spinning at normal speed
FPC 0 Fan Tray 0 Fan 1 OK Spinning at normal speed
--- snipped -----
FPC 1 Fan Tray 0 Fan 0 Absent
FPC 1 Fan Tray 0 Fan 1 Absent
FPC 1 Fan Tray 1 Fan 0 Absent
Issue has been tracked on PR1670917 (https://prsearch.juniper.net/problemreport/PR1670917)
Resolved-In
junos:18.4R3-S9 junos:19.3R3-S3 junos:20.4R2-S1 junos:20.4R3 junos:21.1R3 junos:21.2R2 junos:21.3R1 junos:21.4R1
WORKAROUND
Restart lcmd of the affected member
start shell user root
ps aux | grep lcmd
Then issue, kill -9 <PID>
08/08/2023 - KB Created