The following message is seeing on syslog:
%PFE-5: fpc1 Performing action log for error /fpc/1/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_FABRORD1_ECC_PROTECT_FSET_REG_CORRECTED_L2_TABLE (0x210506) in module: PE Chip with scope: pfe category: processing level: minor
You will see the following messages on your syslog:
fpc1 Error: /fpc/1/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_FABRORD1_ECC_PROTECT_FSET_REG_CORRECTED_L2_TABLE (0x210506), scope: pfe, category: processing, severity: minor, module: PE Chip, type: Description for PECHIP_CMERROR_FABRORD1_ECC_PROTECT_FSET_RE
fpc1 Cmerror Op Set: PE Chip: PE5[5]: FABRORD[1-REQ]:ecc: 0x00000080: Corrected L2 Table (URI: /fpc/1/pfe/0/cm/0/PE_Chip/5/PECHIP_CMERROR_FABRORD1_ECC_PROTECT_FSET_REG_CORRECTED_L2_TABLE)
fpc1 Performing action log for error
These logs refer to an transient ECC error. These errors are typically autocorrected by software automatically and usually no further action is needed on your end and these entries should cease to appear.
You can also reboot the line card to clear the transient error.
07/14/2023 - kb created