This article explains the Major alarm "Fan Tray [X] Fan [X] Not Spinning" and "Fan Tray [X] is not present" and ways to mitigate the alarm.

Symptoms

The following alarms will be raised on the device:

 

root@device> show chassis alarms no-forwarding

2 alarms currently active

Alarm time        Class Description


2023-06-07 17:42:18 UTC Major Fan Tray 0 is not present

2023-06-07 17:42:17 UTC Major Fan Tray 0 Fan 1 Not Spinning

2023-06-07 17:42:17 UTC Major Fan Tray 0 Fan 0 Not Spinning

 

Environment output shows the below snippet:

 

Fans Fan Tray 0           Failed

   Fan Tray 1           OK     Spinning at normal speed

   Fan Tray 2           OK     Spinning at normal speed

 

Logs:

 

Jun 7 17:42:17 device craftd[8450]: %DAEMON-4: Receive FX craftd set alarm message: color: 1 class: 100 object: 144 slot: 0 silent: 0 short_reason=Fan Tray 0 Fan 0 fa long_reason=Fan Tray 0 Fan 0 Not Spinning id=218103952 reason=218103808

Jun 7 17:42:17 device craftd[8450]: %DAEMON-4: Major alarm set, Fan Tray 0 Fan 0 Not Spinning -----------------------------------> Major Alarm Set

Jun 7 17:42:17 device alarmd[8449]: %DAEMON-4: Alarm set: FAN id=218103952, color=RED, class=CHASSIS, reason=Fan Tray 0 Fan 0 Not Spinning

Jun 7 17:42:17 device craftd[8450]: %DAEMON-4: Major alarm set, Fan Tray 0 Fan 1 Not Spinning ------------------------------------> Major Alarm Set

Jun 7 17:42:17 device alarmd[8449]: %DAEMON-4: Alarm set: FAN id=218103952, color=RED, class=CHASSIS, reason=Fan Tray 0 Fan 1 Not Spinning



Jun 7 17:42:18 device alarmd[8449]: %DAEMON-4: Alarm set: FAN id=83886224, color=RED, class=CHASSIS, reason=Fan Tray 0 is not present

Jun 7 17:42:18 device craftd[8450]: %DAEMON-4: Receive FX craftd set alarm message: color: 1 class: 100 object: 144 slot: 0 silent: 0 short_reason=Fan Tray 0 Absent long_reason=Fan Tray 0 is not present id=83886224 reason=83886080

Jun 7 17:42:18 device craftd[8450]: %DAEMON-4: Major alarm set, Fan Tray 0 is not present -------------------------------> Major Alarm Set

 

 

Solution

To clear the alarm, please follow the below steps:

 

  1. Physically check if the fan is not spinning or it is a false alarm.
  2. Please manually reseat the fan tray as they are hot-removable
  3. Remove FAN Tray [X] and check the slot properly if it is damaged. Pins connected to "Fan Tray [X] Fan [X]" is damaged.(Click pictures if possible)
  4. Check if damage is on Chassis side (Click pictures if possible)
  5. Please swap FAN tray [X] into FAN Tray [X+1]/[X-1] slot and check if the alarm follows the slot or stays in the same slot.If the alarm follows the slot, it is Fan Tray issue and we can proceed with Fan Tray replacement.
  6. If swapping the fan tray with a known good one still does not resolve the issue, then the fault can be with the chassis.
  7. But if issue is with chassis,. you should see similar issue again on "Fan Tray 0 Fan 0" . Then we can go ahead and create RMA for chassis depending on the outcomes.

Please open a case with Juniper Technical support  JTAC Support for further investigation and assistance in opening RMA. 

 

 

 

 

Modification History

Initial Draft - 20/06/23