On QFX Series Switches, EX4300 and EX4600 platforms, the following logs indicate that a parity error was corrected by the software.
The following logs are observed:
time switch : %PFE-3: fpc0 Parity error..
time switch : %PFE-3: fpc0 Error in: miscellaneous transaction.
time switch : %PFE-3: fpc0 Blk: 1, Pipe: 0, Address: 0x1c00abc8, base: 0x0, stage: 7, index: 43976
time switch : %PFE-3: fpc0 Unit 0: mem: 2006=L2X blkoffset:10
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 35784
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 43976
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 52168
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 60360
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 68552
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 76744
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 84936
time switch : %PFE-3: fpc0 Unit 0: CLEAR_RESTORE: L2X[2006] start_index: 93128
These logs indicate that a parity error was corrected by the software. These logs do not indicate a degraded state and no further action is needed.
For further reference, please review the following documentation:PR1245098 - Parity error is seen in miscellaneous transaction CLEAR_RESTORE: L2X[2006] start_index: 35784https://prsearch.juniper.net/problemreport/PR1245098
06/04/23 Article Created
PR related to these logs - https://prsearch.juniper.net/problemreport/PR1245098