On QFX series switch, no alarm would be raised even though inserted PSU or FAN module which has a different airflow. This is unexpected and a software bug.
This KB describes the issue details and share the potential PRs that have the fix.
On QFX series switch, no alarm would be raised even if inserted power supply or FAN module with different airflow.Here is the sample output in case of PSU:
Power Supply 0 REV 04 740-041741 1GA27332679 JPSU-650W-AC-AFO Power Supply 1 REV 04 740-044332 1GA15367420 JPSU-650W-AC-AFI <<<= Airflow mismatch
root> show chassis alarms No alarms currently active <==================================================== No airflow errors
Expected output is the following:
root> show chassis alarms no-forwarding 1 alarms currently active Alarm time Class Description 2023-04-26 04:10:08 PDT Major FPC0: PEM: Airflow Direction Mismatch
Here is the sample output in case of FAN:
Fan Tray 0 QFX5120-32C Fan Tray 0, Front to Back Airflow - AFO <================ Airflow mismatch Fan Tray 1 QFX5120-32C Fan Tray 1, Back to Front Airflow - AFI Fan Tray 2 QFX5120-32C Fan Tray 2, Back to Front Airflow - AFI Fan Tray 3 QFX5120-32C Fan Tray 3, Back to Front Airflow - AFI Fan Tray 4 QFX5120-32C Fan Tray 4, Back to Front Airflow - AFI Fan Tray 5 QFX5120-32C Fan Tray 5, Back to Front Airflow - AFI
root> show chassis alarms no-forwarding 1 alarms currently active Alarm time Class Description 2023-04-18 10:19:38 IST Major FPC 0 Fan Airflow direction mismatch