This article discusses the following syslog error, which is seen on QFX5110 platforms:
Jul 29 12:35:48.371 Switch : %PFE-3: fpc0 sbus ack not received within configured time.
On QFX5110 platforms, the following messages are seen on the syslog:
Jul 29 12:35:48.370 Switch : %PFE-3: fpc0 0:_cmicm_sbusdma_reg_array_read: Jul 29 12:35:48.371 Switch : %PFE-3: fpc0 L2_ENTRY.ipipe0 failed(ERR) Jul 29 12:35:48.371 Switch : %PFE-3: fpc0 0:cmicm_sbusdma_error_details: Jul 29 12:35:48.371 Switch : %PFE-3: fpc0 sbus ack not received within configured time. Jul 31 14:08:27.426 Switch : %PFE-3: fpc0 0:_cmicm_sbusdma_wait: Jul 31 14:08:27.426 Switch : %PFE-3: fpc0 failed(ERR) Jul 31 14:08:27.427 Switch : %PFE-3: fpc0 0:cmicm_sbusdma_error_details: Jul 31 14:08:27.427 Switch : %PFE-3: fpc0 0:_cmicm_sbusdma_reg_array_read: Jul 31 14:08:27.427 Switch : %PFE-3: fpc0 Received sbus ack has wrong opcode. Jul 31 14:08:27.427 Switch : %PFE-3: fpc0 0:cmicm_sbusdma_error_details: Jul 31 14:08:27.428 Switch : %PFE-3: fpc0 Received sbus ack data size is not the same as in rep_words fields. Jul 31 14:08:27.428 Switch : %PFE-3: fpc0 0:_soc_sbusdma_desc: Jul 31 14:08:27.428 Switch : %PFE-3: fpc0 soc_sbusdma_desc:IP COUNTERS Error Jul 31 14:08:27.428 Switch : %PFE-3: fpc0 0:_soc_sbusdma_port_ctr_cb: Jul 31 14:08:27.429 Switch : %PFE-3: fpc0 Counter SBUSDMA failed: port:17. Jul 31 14:08:27.429 Switch : %PFE-3: fpc0 L2_ENTRY.ipipe0 failed(ERR) Jul 31 14:08:27.429 Switch : %PFE-3: fpc0 0:cmicm_sbusdma_error_details: Jul 31 14:08:27.429 Switch : %PFE-3: fpc0 sbus ack not received within configured time.
The CMIC DMA error messages and the L2_ENTRY error messages are related. They appeared to have occurred due to high load on L2_TABLE access. As a result, the CMIC did not receive the proper ACK messages within the set timeout interval for the DMA-requests that it had issued. This is the reason for the logging of these error messages.
If these messages are seen intermittently, they can be ignored. It does not interrupt service and is gracefully handled by the device.
If they are are seen continuously, contact your JTAC Representative to investigate further.