The alarm, ' CB 1 CPU Die Temp Sensor Access Failed ' is seen after a reboot.
CB 1 CPU Die Temp Sensor Access Failed
The following alarm appears on the chassis once a system (usually on VMhost based platforms) comes up after a reboot (for Junos upgrade) and the temp sensor on the CB is not detected correctly.
@router-name> show chassis alarms 3 alarms currently active Alarm time Class Description 2021-03-29 16:23:13 PDT Major CB 1 CPU Die Temp Sensor Access Failed 2021-03-29 16:23:13 PDT Major CB 0 CPU Die Temp Sensor Access Failed
Restart the LCMD process by logging into the host prompt
> start shell user root # vhclient -s <--- This will take you to the vmhost prompt. root@router-node:~# cd /var/tmp root@router-node:/var/tmp# systemctl status lcmd ● lcmd.service - lcmd service Loaded: loaded (/usr/sbin/lcmd; static; vendor preset: enabled) Active: active (running) since Wed 2021-07-28 05:33:12 SAST; 2 days ago Main PID: 4421 (lcmd) CGroup: /system.slice/lcmd.service └─4421 lcmd root@router-01-node:/var/tmp# systemctl restart lcmd root@router-01-node:/var/tmp# systemctl status lcmd ● lcmd.service - lcmd service Loaded: loaded (/usr/sbin/lcmd; static; vendor preset: enabled) Active: active (running) since Fri 2021-07-30 07:13:01 SAST; 36s ago Process: 26495 ExecStop=/etc/init.d/lcmd stop (code=exited, status=0/SUCCESS) Process: 26510 ExecStart=/etc/init.d/lcmd restart (code=exited, status=0/SUCCESS) Main PID: 26524 (lcmd) CGroup: /system.slice/lcmd.service └─26524 lcmd
If the step above does not clear the alarm, try the following:
If the alarms are still not cleared, collect the RSI, var/log and contact your JTAC Representative for further investigation.