This article explains why the "DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(13)" log message may be seen on VC-Mm or the new Primary routing engine (RE) for empty FPC slots, after a local switchover or a global switchover on MX-VC devices.
It also clarifies that these logs are expected after local or global switchover, and have no service impact.
On VC-Bs, execute local primary role switchover:
{local:member1-re0} root@router-re0> request chassis routing-engine master switch Jul 17 19:32:46 Toggle mastership between routing engines ? [yes,no] (no) yes Jul 17 19:32:47
On VC-Mm, the following log is observed:
Jul 17 19:34:29.176 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(17) Jul 17 19:34:29.184 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(18) Jul 17 19:34:29.190 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(19) Jul 17 19:34:29.197 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(20) Jul 17 19:34:29.204 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(21) Jul 17 19:34:29.211 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(22) Jul 17 19:34:29.217 jtac-mx480-r2040-re0 scchassisd[14343]: %DAEMON-5-CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(23)
In the above output, FPC 17 to FPC 23 are empty slots in MX-VC.
When doing a global switchover, the same logs will also show on the new primary Routing Engine.
During a local or global switchover on MX-VC, the chassisd daemon needs to fall back to a clean start, and therefore, cycles through all potential line cards, whether they are present or not. The above log message is reported for a potential line card when the daemon cycles through the cards.
This is expected behavior, and has no service impact on MX-VC. The device is functioning as per design.
This log will also appear when the RE reboots, because the chassisd daemon cycles through all potential line cards when the RE reboots.
No action is required because these logs are expected during VC local and global switchover, and there is no service impact. They can be safely ignored.