This article describes an issue wherein the EX3400 Series device's port LED continues to be on even after completely halting the device, and indicates that the solution is to upgrade to Junos OS 18.1R3-S8 release.
Note: The reproduction rate of the issue is 30% of the time.
After executing the request system halt at now command on EX3400 devices, the port LED continues to remain on.
request system halt at now
The link is connected to other EX3400 switches and these ports are up.
root> show interfaces terse | match "up up" | match ge- ge-0/0/0 up up ge-0/0/0.0 up up eth-switch ge-0/0/1 up up ge-0/0/1.0 up up eth-switch ge-0/0/2 up up ge-0/0/2.0 up up eth-switch ge-0/0/3 up up ge-0/0/3.0 up up eth-switch ge-0/0/4 up up ge-0/0/4.0 up up eth-switch ge-0/0/5 up up ge-0/0/5.0 up up eth-switch ge-0/0/6 up up ge-0/0/6.0 up up eth-switch ge-0/0/7 up up ge-0/0/7.0 up up eth-switch ge-0/0/8 up up ge-0/0/8.0 up up eth-switch ge-0/0/9 up up ge-0/0/9.0 up up eth-switch ge-0/0/10 up up ge-0/0/10.0 up up eth-switch ge-0/0/11 up up ge-0/0/11.0 up up eth-switch ge-0/0/12 up up ge-0/0/12.0 up up eth-switch ge-0/0/13 up up ge-0/0/13.0 up up eth-switch ge-0/0/14 up up ge-0/0/14.0 up up eth-switch ge-0/0/15 up up ge-0/0/15.0 up up eth-switch ge-0/0/16 up up ge-0/0/16.0 up up eth-switch ge-0/0/17 up up ge-0/0/17.0 up up eth-switch {master:0} root> root> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis NX0219160762 EX3400-48T Pseudo CB 0 Routing Engine 0 BUILTIN BUILTIN RE-EX3400-48T FPC 0 REV 24 650-059881 NX0219160762 EX3400-48T CPU BUILTIN BUILTIN FPC CPU PIC 0 REV 24 BUILTIN BUILTIN 48x10/100/1000 Base-T PIC 1 REV 24 650-059881 NX0219160762 2x40G QSFP PIC 2 REV 24 650-059881 NX0219160762 4x10G SFP/SFP+ Power Supply 0 REV 05 640-060603 1EDV91005CA JPSU-150W-AC-AFO Fan Tray 0 Fan Module, Airflow Out (AFO) Fan Tray 1 Fan Module, Airflow Out (AFO) {master:0} root>
Step-1. Execute request system halt at now .
root> request system halt at now warning: This command will halt all the members. If planning to halt only one member use the member option Halt the system at now? [yes,no] (no) yes Stopping cron. . Waiting (max 60 seconds) for system process `vnlru' to stop... done Waiting (max 60 seconds) for system process `bufdaemon' to stop... done Waiting (max 60 seconds) for system process `syncer' to stop... Syncing disks, vnodes remaining... 0 0 0 done All buffers synced. Uptime: 7m11s Khelp module "jsocket" can't unload until its refcount drops from 3 to 0. The operating system has halted. Please press any key to reboot.
Step-2. Check the Link LED. With the above condition, the uplink LED is always on.
Note: The peer device can, however, detect the link down normally.
This problem is fixed in Junos OS release 18.1R3-S8.