Minor alarm "PEM x Feed x switch OFF but input connected" is reported in the show chassis alarms output if the Input (INP) DIP switches are in the OFF position.
show chassis alarms
If the Input (INP) DIP switch is OFF but the feeds are connected, the following minor alarm may be reported:
Alarm time Class Description 2018-01-01 01:01:01 UTC Minor PEM x Feed x switch OFF but input connected
This is a feature introduced with PR1311574 - PTX10K/MX10K: Suppress chassis alarm for switched off PEMS to indicate the Input (INP) switches are set OFF but the feeds are connected.
Setting the INP (DIP) switches ON should clear the alarm.
To find the location of the 1 and 2 switches, refer to the hardware guides:
For an explanation of the LED status of these switches, see:
2021-10-15: Minor typo correction.2023-10-08: Added MX as category and in title