This article describes the behavior of SFP-T link up during boot process on SRX300 and SRX550M series devices.
The SRX300 and SRX550M series with SFP-T module cause early link-up on connecting device. This behavior is seen on following devices:
Sample topology and related logs:
SRX300(SFP-T) --(copper ethernet LAN cable)-- EX3200(ge-0/0/1) (192.168.30.1) (192.168.30.2)
root@SRX300> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis CV3216AF0692 SRX300 Routing Engine REV 0x08 650-065039 CV3216AF0692 RE-SRX300 FPC 0 FPC PIC 0 6xGE,2xGE SFP Base PIC Xcvr 6 REV 01 740-038291 F300683 SFP-T <--- Copper SFP
Reboot SRX300
Link-down detected on EX3200 due to reboot on SRX300. Oct 24 12:15:28 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1.0 index 2147404488 <Broadcast Multicast> address #0 0.19.e2.56.e5.c4 Oct 24 12:15:28 EX3200 rpd[1242]: EVENT UpDown ge-0/0/1.0 index 2147404472 192.168.30.2/24 -> 192.168.30.255 <Broadcast Multicast Localup> Oct 24 12:15:28 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1 index 140 <Broadcast Multicast> address #0 0.19.e2.56.e5.c4
Oct 24 12:15:28 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1.0 index 2147404488 <Broadcast Multicast> address #0 0.19.e2.56.e5.c4 Oct 24 12:15:28 EX3200 rpd[1242]: EVENT UpDown ge-0/0/1.0 index 2147404472 192.168.30.2/24 -> 192.168.30.255 <Broadcast Multicast Localup> Oct 24 12:15:28 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1 index 140 <Broadcast Multicast> address #0 0.19.e2.56.e5.c4
Link-up detected on EX3200 in just a few seconds from SRX300 reboot. Oct 24 12:15:31 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1.0 index 2147404488 <Up Broadcast Multicast> address #0 0.19.e2.56.e5.c4 Oct 24 12:15:31 EX3200 rpd[1242]: EVENT UpDown ge-0/0/1.0 index 2147404472 192.168.30.2/24 -> 192.168.30.255 <Up Broadcast Multicast> Oct 24 12:15:31 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1 index 140 <Up Broadcast Multicast> address #0 0.19.e2.56.e5.c4
Oct 24 12:15:31 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1.0 index 2147404488 <Up Broadcast Multicast> address #0 0.19.e2.56.e5.c4 Oct 24 12:15:31 EX3200 rpd[1242]: EVENT UpDown ge-0/0/1.0 index 2147404472 192.168.30.2/24 -> 192.168.30.255 <Up Broadcast Multicast> Oct 24 12:15:31 EX3200 rpd[1242]: EVENT <UpDown> ge-0/0/1 index 140 <Up Broadcast Multicast> address #0 0.19.e2.56.e5.c4
root@EX3200> show interfaces terse ge-0/0/1
Interface Admin Link Proto Local Remote
ge-0/0/1 up up
ge-0/0/1.0 up up inet 192.168.30.2/24
This behavior is by design.
Take the following workaround to reduce possible risks considering actual network topology:
Using built-in copper port
Replace SFP-T module with optical module. Optical modules do not reproduce this issue.
Setting "hold-time" on the connecting device. The "hold-time" configuration can suppress early link-up until SRX completes its boot process.