The "Cell packing interface error" message reports a transient hardware issue with permanent operational impact. This is a Troubleshooting Article for a PFE ASIC Syslog Event. To view other documented syslog events related to XMCHIP, XLCHIP, MQCHIP, LUCHIP, EACHIP, and PECHIP, see KB31893 - Master Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] . .
When a "Cell packing interface error" event occurs, a message similar to the following is reported: Apr 13 13:41:43.155 router fpc4 XMCHIP(0):XMCHIP(0): FO: Cell packing interface error - data32_err_log 0x11 Indications:
Apr 13 13:41:43.155 router fpc4 XMCHIP(0):XMCHIP(0): FO: Cell packing interface error - data32_err_log 0x11
PFE wedge of the fabric output block and traffic forwarding is permanently compromised
Alarm will be raised
If this is caused by a transient hardware error, then additional syslog parity events will be reported. If such events are not combined with a parity error syslog message, then the trigger is a software defect not handling properly the packet head going through the lookup and packet tail located at the memory of the XMCHIP center-chip.
{DIDYOUKNOWSERVICENOWTOKEN.EN_US} The following Junos software changes have been performed to avoid such exposure:
To avoid this exposure disable cell-sharing on MPC2E-NG/MPC3E/MPC4E/MPC5E/MPC6E with the following configuration "set chassis fpc 'slot#' fabric no-cell-share" . A system reboot is needed to activate this configuration. In Junos OS version 17.4 or higher, cell-sharing is disabled per default on all linecards with XMCHIP
"set chassis fpc 'slot#' fabric no-cell-share"
Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "Cell packing interface error" message. Frequently these events help identify the cause.
No RMA is required
The generic pfe-disable event script will detect the wedge condition that happens as a result of this event and invoke the pfe-disable action; see KB31867 - Generic pfe-disable Event Script [juniper.net] . A FPC restart at a later time is needed to bring the PFE back into service.
Perform FPC restart to recover.
Contact your technical support representative.
This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag XMCHIPTSG
2019-10-14: JunOS software changes implemented to avoid this exposure; updated this KB