The "lmem data error" message is caused by a transient hardware error which is automatically repaired.This is a Troubleshooting Article for a PFE ASIC Syslog Event. To view other documented syslog events related to XMCHIP, XLCHIP, MQCHIP, LUCHIP, EACHIP, and PECHIP, see KB31893 - Master Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ..
When a "lmem data error " event occurs, messages similar to the following are reported:XLCHIP:
Sep 7 17:11:38.269 router : %PFE-3: fpc8 XL[0:0]_PPE 0 Errors lmem data error 0x00000082Sep 7 17:11:38.269 router : %PFE-3: fpc8 ppe_lmem_recover(2469) XL[0:0]_PPE 0 Excessive LMEM Data errors require Zone 1 disable.orSep 7 17:11:38.269 router : %PFE-3: fpc8 ppe_lmem_recover(2469) XL[0:0]_PPE 0 too many shared LMEM errors, disabling.
EACHIP:
Sep 7 17:11:38.269 router : %PFE-3: fpc8 EA[0:0]_PPE 0 Errors lmem data error 0x00000082Sep 7 17:11:38.269 router : %PFE-3: fpc8 ppe_lmem_recover(2469) EA[0:0]_PPE 0 Excessive LMEM Data errors require Zone 1 disable.orSep 7 17:11:38.269 router : %PFE-3: fpc8 ppe_lmem_recover(2469) EA[0:0]_PPE 0 too many shared LMEM errors, disabling.
LUCHIP:
Sep 7 17:11:38.269 router : %PFE-3: fpc8 LUCHIP(0) PPE 0 Errors lmem data error 0x00000082Sep 7 17:11:38.269 router : %PFE-3: fpc8 LUCHIP(0) LMEM errors require LUCHIP(0) PPE 0 Zone 0 disableorSep 7 17:11:38.269 router : %PFE-3: fpc8 LUCHIP(0) SHARED LMEM errors require LUCHIP(0) PPE 0 Zone 0 disable
Indications:
No service impact
This error is a transient hardware problem and gets automatically corrected.
The alarm is raised once specific zones have many repairs, then the specific zone is disabled.
If the specific zone is a shared zone, then the corresponding PPE will get disabled.
This error is caused by a transient hardware error. LMEM data errors are parity errors and the software will repair those errors automatically.
{DIDYOUKNOWSERVICENOWTOKEN.EN_US}
Perform these steps to determine the cause and resolve the problem (if any). Continue through each step until the problem is resolved.
Collect the show command output.
Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.
show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit
Analyze the show command output.
In the 'show log messages', review the events that occurred at or just before the appearance of the "lmem data error " message. Frequently these events help identify the cause.
No RMA is required for couple incidents
Collect trap debug file in /var/tmp directory. Refer to KB31922 - shell script collecting data if packet forwarding at Packet Forwarding Engine is compromised [juniper.net]
Contact your technical support representative to RMA the FPC if zones are disabled.
This article is indexed in KB31893 - primary Index of Articles for Troubleshooting PFE ASIC Syslog Events [juniper.net] ; tag EACHIPTSG XLCHIPTSG LUCHIPTSG